Schneider Electric User Guide
Configuration
3–4 975-0240-01-01
For more information, see “Setting the Time” and “Setting the Date” in the Conext
System Control Panel Owner’s Guide.
Using the Setup Menus
Basic menu The Conext XW+ configuration settings can be viewed in basic and advanced
formats (see Figure 3-3, “Basic and Advanced Settings” on page 3–7). The basic
settings include configuration items you may have to adjust routinely, or as part of
initial setup.
Advanced menu The advanced settings option gives you access to the full range of Conext XW+
settings, including everything displayed on the basic menu. As a safeguard
against unintended advanced configuration, the Conext SCP displays the basic
settings by default. To view the advanced settings, you must perform a special
keypress.
Note: Network time on the ComBox overrides time configured on any individual
device in the network-enabled power system using network time protocol (NTP).
If your device is not compatible with NTP, Conext XW+ features such as peak
load shaving and charger block may not work correctly, and charge controller
daily power production values may reset at an unexpected time. If your device is
working incorrectly, configure the ComBox to use the local time and date. See the
ComBox Owner’s Guide (document part number: 975-0679-01-01) for more
information.
WARNING
ADVANCED CONFIGURATION HAZARD
Advanced menu settings should be used by qualified personnel only.
Three phase operation should be configured by qualified personnel only.
Consult with the local utility before enabling Conext XW+ sell mode or grid
support functions.
Do not change these settings unless you are under the supervision and
direction of qualified personnel.
Failure to follow these instructions can result in death or serious injury.
Conext XW+ Owner's Guide NA (975-0240-01-01).book Page 4 Monday, November 27, 2017 10:00 AM