Conext PreWired Quick Fit Data Sheet
Technical Specications
Conext™ Quick Fit for North America
© 2019 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries
SAS or its aliated companies. All information is preliminary and will need to be conrmed at the time of order.
DS20190225_Conext Quick Fit.indd
Conext™ Quick Fit for North America | 2
For indoor use only
Device short name
Conext™ Quick Fit
XW+ H
Conext™ Quick Fit
XW+ L
Conext™ Quick Fit
SW 4048
Conext™ Quick Fit
SW 4024
Conext™ Quick Fit
XW Pro H
Conext™ Quick Fit
XW Pro L
General specications
Part number 865-6848-01HPS 865-6848-01LPS 865-4048LPS 865-4024LPS 865-6848-21HPS 865-6848-21LPS
Product weight 108.2 kg / 238.4 lb 104.3 kg / 229.8 lb 79.4 kg / 174.9lb 79.4 kg / 174.9 lb 108.2 kg / 238.4 lb 104.3 kg / 229.8 lb
Shipping weight 163.5 kg / 360.4 lb 159.6 kg / 351.8 lb 134.7 kg / 296.9 lb 134.7 kg / 296.9 lb 163.5 kg / 360.4 lb 159.6 kg / 351.8 lb
Product dimensions (H x W x D) 117.9 x 89.8 x 30.5 cm / 46.4 x 35.3 x 12.0 in 117.9 x 89.8 x 26.8 cm / 46.4 x 35.3 x 10.6 in 117.9 x 89.8 x 30.5 cm / 46.4 x 35.3 x 12.0 in
Shipping dimensions (H x W x D) 121.9 x 101.6 x 50.8 cm / 48 x 40 x 20 in 121.9 x 101.6 x 50.8 cm / 48 x 40 x 20 in 121.9 x 101.6 x 50.8 cm / 48 x 40 x 20 in
Included Products
Conext™ hybrid inverter
1 x Conext™ XW+ 1 x Conext™ XW+ 1 x Conext™ SW 4048 1 x Conext™ SW 4024 1 x Conext™ XW Pro 1 x Conext™ XW Pro
Conext™ Charge controller
1 x MPPT 80 600 2 x MPPT 60 150 1 x MPPT 60 150 1 x MPPT 60 150 1 x MPPT 80 600 2 x MPPT 60 150
Conext™ Power Distribution Panel
1 x Conext™ XW+ PDP 1 x Conext™ XW+ PDP 1 x Conext™ SW PDP 1 x Conext™ SW PDP 1 x Conext™ XW+ PDP 1 x Conext™ XW+ PDP
Conext™ Monitoring device 1 x Conext™ ComBox 1 x Conext™ ComBox - - 1 x Conext™ Gateway 1 x Conext™ Gateway
Conext™ SCP 1 1 1 1 1 1
Conext™ Battery Monitor 1 1 - - 1 1
Backplate 1 1 1 1 1 1
Features
System monitoring and network
communications
Available
Intelligent features Grid sell (XW+ and XW Pro models only), peak load shave, generator support, prioritized consumption of battery or external DC energy
Auxiliary port 0 to 12 V, maximum 250 mA DC output, selectable triggers
Off-grid AC coupling Frequency control
Regulatory approval
Safety UL1741, CSA 107.1
EMC directive FCC and Industry Canada Class B
Interconnect IEEE 1547, UL 1741-SA, and CSA 107.1
865-4048LPS
865-4024LPS
865-6848-01HPS 865-6848-01LPS 865-6848-21HPS 865-6848-21LPS