Conext XW+ 230V Installation Guide
Table Of Contents
- Conext™ XW
- Inverter/Charger
- Conext™ XW
- Inverter/Charger
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Conext XW+ Features
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Battery Fuse Disconnect Box (250A)
- Battery Fuse Disconnect Box (160A)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Basic Functional Test – Single Inverter
- Basic Functional Test - Multiple Inverters
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Pre-Installation Steps
- Conext XW+ Power Distribution Panel Internal Faceplate Removal
- Conext XW+ Inverter/Charger Grounding
- Making DC Connections with a PDP
- Single Inverter/Charger DC Connections
- Dual Inverter/Charger DC Connections
- Triple Inverter/Charger DC Connections
- AC Wiring with a Conext XW+ Power Distribution Panel
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
Specifications
A–8 975-0714-01-01
This manual is for use by qualified personnel only
Accessories
Regulatory Approvals
CE marked and complies with the following:
Low Voltage Directive 2014/35/EU, per:
• EN62109-1 Power converters used in photovoltaic systems
• EN62109-2 Particular requirements for Inverters
• EN60529 Degrees of protection by enclosures
EMC Directive 2014/30/EU, per:
• EN61000-6-3 “Emission Standard for Residential, Commercial, and
Light-Industrial Environments”
• EN61000-6-1 “Immunity for Residential, Commercial, and Light-Industrial
Environments”
RCM marked and complies with the following:
• AS 4777.2: 2015 “Inverter requirements”
• IEC 62109-1: 2010 “General Requirements”
• IEC 62109-2: 2011 “Particular Requirements for Inverters”
• AS/NZS 60335.2.29:2004 + A1&A2 “Particular Requirements for Battery
Chargers”
• Registered with the Clean Energy Council
Table A - 3 Conext XW+ Accessories
Accessory Part Number
Conext XW+ Power Distribution Panel 865-1015-01
Conext XW+ Power Distribution Panel (Without
AC Breakers)
865-1014-01
Conext XW+ Conduit Box 865-1025-01
Conext XW+ Connection Kit for INV2 INV3 PDP 865-1020-02
Conext System Control Panel 865-1050-01
Conext Automatic Generator Start 865-1060-01
Conext MPPT 60 150 Solar Charge Controller 865-1030-1
Conext MPPT 80 600 Solar Charge Controller 865-1032
Conext ComBox 865-1058
Conext Battery Monitor 865-1080-01