Conext XW+ 230V Installation Guide
Table Of Contents
- Conext™ XW
- Inverter/Charger
- Conext™ XW
- Inverter/Charger
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Conext XW+ Features
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Battery Fuse Disconnect Box (250A)
- Battery Fuse Disconnect Box (160A)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Basic Functional Test – Single Inverter
- Basic Functional Test - Multiple Inverters
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Pre-Installation Steps
- Conext XW+ Power Distribution Panel Internal Faceplate Removal
- Conext XW+ Inverter/Charger Grounding
- Making DC Connections with a PDP
- Single Inverter/Charger DC Connections
- Dual Inverter/Charger DC Connections
- Triple Inverter/Charger DC Connections
- AC Wiring with a Conext XW+ Power Distribution Panel
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
Wiring the Conext XW+ Inverter/Charger
3–4 975-0714-01-01
This manual is for use by qualified personnel only
Communication Ports and BTS Port
There are five communication ports and a Battery Temperature Sensor (BTS) port
located on the bottom of the Conext XW+ chassis (as shown above in Figure
3-2):
Two Xanbus ports for making network connections between inverters, charge
controllers, and accessories. For more information, see Chapter 4, “Xanbus
Network Installation”.
Two AC sync ports to connect multiple Conext XW+ Inverter/Chargers in parallel.
For installation instructions, see “Installing AC sync and Xanbus cables” on
page 4–5.
AUX port: 12 VDC/250 mA output to control a relay, fan, indicator light, or other
device, using a Conext System Control Panel (SCP) or Conext ComBox. For more
information, see “AUX Port” on page 3–4.
Battery Temperature Sensor (BTS) port: For more information, see “Battery
Temperature Sensor Installation” on page 3–9.
AUX Port
The Conext XW+ Inverter/Charger has a 12 VDC auxiliary (AUX) output that can
be configured to trigger in response to one of the following conditions:
• low battery voltage
• high battery voltage
• low battery temperature
• high battery temperature
• charge bulk exit
• charge absorption exit
• heatsink temperature
• TOD (time of day)
• SOC (state of charge)
The auxiliary output can also be triggered manually using a Conext System
Control Panel or ComBox.
Figure 3-2 Conext XW+ Inverter/Charger communication ports
AUX port
AC sync port
Xanbus ports
BTS port
Note: The AUX port is connected via an AUX port connector, included with the
Conext XW+ Inverter/Charger.