BRS3 4 Installation
3-phase stepper motor 53
4.1 Before mounting
Checking for damage Damaged drive systems must neither be installed nor operated.
왘 Prior to mounting, check the drive system for visible damage.
Checking the holding brake (option) See chapter 8.2 "Maintenance", "Checking/running in the holding
brake".
Cleaning the shaft The motor shafts are factory-treated with an anti-corrosive. If output
components are glued to the shaft, the anti-corrosive must be removed
and the shaft cleaned. If required, use a grease removal agent as spec-
ified by the glue manufacturer. If the glue manufacturer does not provide
information on grease removal, it is recommended to use acetone.
왘 Remove the anti-corrosive. Avoid direct contact of the skin and the
sealing material with the anti-corrosive or the cleaning agent.
Mounting surface for flange The mounting surface must be stable, clean and low-vibration.
왘 Verify that the system side meets all requirements in terms of
dimensions and tolerances.