Manual

Table Of Contents
0198441113730, V2.02, 03.2011
BRS3 4 Installation
3-phase stepper motor 57
Mounting When the motor is mounted to the mounting flange, it must be accurately
aligned and have full-surface contact. There must no tension. The
mounting flange as well as the parts mounted to the shaft must be rated
for the dynamic loads that may result during operation.
Mounting output components If output components are not properly mounted, the encoder may be
damaged. Output components such as pulleys, couplings must be
mounted with suitable equipment and tools. The maximum axial and ra-
dial forces acting on the shaft must not exceed the maximum shaft load
values specified, see 3.8.2 "Shaft load".
Observe the mounting instructions provided by the manufacturer of the
output component. Motor and output component must be accurately
aligned both axially and radially. Failure to follow the instructions will
cause runout, damage to the rolling bearings and premature wear.