Instruction manual
Installation Instructions
35
Absolute Source selection is a little more complicated, as it is best
performed using a scene. To configure a button that selects an
absolute source using a scene:
i) Select the Scene function for the button. (Note that a button is
referred to as a key in some versions of Toolkit).
ii) Click the
Properties button next to the Function. This brings
up the “Define a Scene” panel. If you are using a C-Bus DLT wall
switch, you must select a Trigger Group and Trigger Group
Action Selector on this panel so you can send labels to the DLT
later. Use the Group Address and selector(s) you created in
Step 4. An example is provided in
Figure 30.
iii)
Click the Edit Scenes button to bring up the Scene Manager.
Select the Group Address used for Absolute Source selection
(from the list on the right hand side), and click the “<” button to
add it to the list of Commands. Type the level which
corresponds to the relevant source, in the box next to the
slider. Absolute source levels can be seen in
Figure 26.
Figures 31 and 32 show
the configuration of the Ulti Saturn wall
switch used in Zone 2 of the MRA example system.
Figure 30 – Defining a scene on a DLT