[Ui] rated insulation voltage Power circuit 690V IEC 60947-4-1
Power circuit: 600V CSA certified
Power circuit: 600V UL certified
Signalling circuit 690V IEC 60947-1
Signalling circuit 600V CSA
Signalling circuit 600V UL
Electrical durability 0.6Mcycles 20A AC-1 <= 440 V
1Mcycles 9A AC-3 <= 440 V
Power dissipation per pole 1.56W AC-1
0.2W AC-3
Mounting support Rail
Plate
Connections - terminals Power circuit: screw clamp terminals 1 1…4mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 2 1…4mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 1 1…4mm² - cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 2 1…2.5mm² - cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 1 1…4mm² - cable stiffness: solid without
cable end
Power circuit: screw clamp terminals 2 1…4mm² - cable stiffness: solid without
cable end
Control circuit screw clamp terminals 1 0.00…0.01in² (1…4mm²) flexible without
cable end
Control circuit screw clamp terminals 2 0.00…0.01in² (1…4mm²) flexible without
cable end
Control circuit screw clamp terminals 1 0.00…0.01in² (1…4mm²) flexible with
cable end
Control circuit screw clamp terminals 2 0.00…0.00in² (1…2.5mm²) flexible with
cable end
Control circuit screw clamp terminals 1 0.00…0.01in² (1…4mm²) solid without
cable end
Control circuit screw clamp terminals 2 0.00…0.01in² (1…4mm²) solid without
cable end
Tightening torque Power circuit 15.05lbf.in (1.7N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05lbf.in (1.7N.m) screw clamp terminals Philips No 2
Control circuit 15.05lbf.in (1.7N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05lbf.in (1.7N.m) screw clamp terminals Philips No 2
Operating time 12...22 ms closing
4...19 ms opening
Safety reliability level B10d = 1369863cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 10Mcycles
Maximum operating rate 3600cyc/h 140°F (60°C)
Coil technology Without built-in suppressor module
Control circuit voltage limits Drop-out 0.3...0.6 Uc 50/60 Hz 158°F (70°C))
Operational 0.8...1.1 Uc 50 Hz 140°F (60°C))
Operational 0.85...1.1 Uc 60 Hz 140°F (60°C))
Operational 1...1.1 Uc 50/60 Hz 158°F (70°C))
Inrush power in VA 70VA 60 Hz 0.75 68°F (20°C))
70VA 50 Hz 0.75 68°F (20°C))
Hold-in power consumption in VA 7.5VA 60 Hz 0.3 68°F (20°C))
7VA 50 Hz 0.3 68°F (20°C))
Auxiliary contacts type Type mechanically linked 1 NO conforming to IEC 60947-5-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5mA for signalling circuit
Minimum switching voltage 17V signalling circuit
Non-overlap time 1.5Ms on de-energisation between NC and NO contact
1.5ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor open 10 Gn for 11 ms)
Shocks contactor closed 15 Gn for 11 ms)
Height 3.03in (77mm)
Width 1.77in (45mm)
Depth 3.39in (86mm)
Net weight 0.71lb(US) (0.32kg)