User manual

9
Model Number Codes
Part B – E Series Overview
D, E & M Series Data Radios - Part Number Matrix = Tyxxx-aabbb-cdef
T y xx z- aa bbb- cd e
Options - Hot Standby Configurations*
Options - Base Stations* 0 = No Options
0 Duplexer Antenna
1
5
Number Type
Antenna
Config Antenna Type
6 A - - - Separate Tx & Rx
A
B - - Dual [x4] Separate Tx & Rx
C Single Internal Single Combined Tx/Rx
Options - E and M Series Remotes
D Dual [x2] Internal Dual [x2] Combined Tx/Rx
0 = No Options F Dual [x2] External Dual [x2] Combined Tx/Rx
H
Options*
E = Diagnostics and Encryption - [DIAGS/E or DIAGS/EH] (E Series Only) ***
X = Full Duplex Operation and Diagnostics (E-Series Remotes only)
Y = Full Duplex Operation, Diagnostics and Encryption [ERFD450 & DIAGS/E] (E-Series Remotes only) ***
L = Sleep Mode Module + Diagnostics (MR450 only)
D = Diagnostics
RF Channel Data Rate & Bandwidth (Internal Modem)
E Series M Series~~
D Series A01 000
= Analog Only 12.5kHz (Local Diags included - No Additional Charge)
A01
= ACA 4800bps 12.5kHz
A02 001
= 2400bps 12.5KHz / 4800bps 25kHz
A02
= ACA 9600bps 25kHz
F01 002
= 4800bps 12.5KHz / 9600bps 25kHz
F01
= FCC 9600bps 12.5kHz
F02 003
= FCC 9600bps 12.5KHz
E01 004
= ETSI 4800bps 12.5KHz
241*
= 2400bps 12.5KHz (S Series [24SR]* Compatible) c/w Local Diags
242*
= 2400bps 25KHz (S Series [24SR]* Compatible) c/w Local Diags
= 450MHz 20W RF Power Output
= 450MHz Band Reject
Duplexer [DUPLX450BR]
= 900MHz Band Pass Compact Duplexer [DUPLX900BPC]
= 900MHz Band Pass Duplexer (76MHz split)[DUPLX852/930]
= No Options
= FCC 19k2bps 25kHz
= ETSI 4800
#
/ 9600 bps 12.5kHz
= Hazardous Environment Class 1, Div 2 and Diagnostics
Available ONLY and standard on ER & MR450-aa-000 to 004
= ACA 4800
#
/ 9600bps 12.5kHz
= FCC 9600
#
/ 19K2bps 12.5kHz
= ACA 9600
#
/ 19k2bps 25kHz
242*
= 2400bps 25KHz (S Series [24SR]* Compatible) c/w Local Diags
482*
= 4800bps 25KHz (S Series [48SR]* Compatible) c/w Local Diags
Frequency Bands E Series (400MHz) M Series (400MHz)
D Series (900MHz)
46
M
= 400 to 470MHz (Tx & Rx) (M Series Only)
07
47
H
= 450 to 520MHz (Tx & Rx) (M Series Only)
06
50
63
64
56
57
55
Model Sub-Type
51
0 = Serial Interface Only 65
e = Ethernet & Serial Interface (E Series Only) 52
53 Note: Other frequency bands available on request
60
54
Generic Frequency Band
NOTES:
45 = 450MHz UHF Band (E & M Series only) * Additional charges apply. Must be ordered separately. Please refer to price list.
90 = 800-900MHz Band (D Series only) ** Consult factory for availability.
*** Export restrictions may apply.
#
Provides compatibility with D and/or M Series radios
[ ] Items in [ ] parenthesis refer to actual Trio part numbers
Unit Type
~~ M Series Compatible EB/EH450 Base Stations are Type A01 or F01
R = Remote Station
B = Base / Repeater Station (D, E & M Series Only) Standards: ACA - Australian Communications Authority
H = Hot Standby Base / Repeater (D, E & M Series Only) FCC - Federal Communications Commission
ETSI - European Telecommunication Standards Institute
Model Type
D = D Series Family
E = E Series Family
M = M Series Family
Example:
= 406 to 421MHz (Tx & Rx)
= 465 to 480MHz (Tx & Rx)
= 418 to 435MHz (Tx & Rx)
= 403 to 417MHz (Tx & Rx)
= (Tx) 847 to 857MHz (1W)
(Rx) 923 to 933MHz (Full Duplex)
= (Tx) 923 to 933MHz (1W)
(Rx) 847 to 857MHz (Full Duplex)
= 455 to 470MHz (Tx & Rx)
= 415 to 430MHz (Tx & Rx)
= 436 to 450MHz (Tx & Rx)
= 370 to 388MHz (Tx & Rx)
= 380 to 396MHz (Tx & Rx)
= 395 to 406MHz (Tx & Rx)
= 490 to 500MHz (Tx & Rx)
= 505 to 518MHz (Tx & Rx)
= 480 to 494MHz (Tx & Rx)
The example shown specifies: E Series, Remote Radio, generic 450MHz band, with a specific frequency of 450MHz
to 465MHz, a 9600/19200bps modem, with a bandwidth of 25kHz, diagnostics and Class 1, Div 2 Hazardous
= 428 to 444MHz (Tx & Rx)
= 450 to 465MHz (Tx & Rx)
Example:
E R 45 0- 51 A02- DH 0
Dwg / Ver: 184-56-0001-H
to 465MHz, a 9600/19200bps modem, with a bandwidth of 25kHz, diagnostics and Class 1, Div 2 Hazardous
Approval (standard).