Installation Guide

14-EN © 2011 Schneider Electric All Rights Reserved
ENGLISH
4. Highlight “Installation Settings” and press [Select] or the Scroll Wheel.
5. Read the warning and press [Continue] to proceed.
6. To exit the Installation Settings menu, press [Back] several times to return to the Home Screen.
NOTE: The thermostat will automatically default to the Home screen after 3 minutes of no key activity.
Thermostat Address (with HAI Home Control Systems. See Page 10.)
If remote communications will be used and more than one thermostat will be installed, each thermostat
must be set to a unique address. The default address setting is 1. An address from 1–127 may be
selected.
Communications Mode (with HAI Home Control Systems. See Page 10.)
The thermostat can communicate with remote systems in different modes. The following modes are
available:
System Options
Before operating the thermostat, the “System Type” and “System Mode” must be configured. The
thermostat can be configured with the following system options.
Communications
*Serial: RS-232 mode for use with personal computers and automation systems.
Day/Night: The thermostat remotely communicates with a remote setback
switch.
System Baud *100 300 1200 2400 9600
Expansion Baud 100 300 *1200 2400 9600
An asterisk (*) next to a setup item indicates the default (factory) setting.
System Type *Conventional
Dual Fuel Heat
Pump
1
1
When configured, an additional Installer Setup menu item (Balance Setpoints) is added
to the list.
Heat Pump
System Mode
*Auto Changeover Auto Changeover
Auto
Changeover
Manual Changeover Manual Changeover
Manual
Changeover
Heat Only
Cool Only
Fan On with Heat
Stage
*None 1 2
1
and
2
12
1
and
2
12
1
and
2
An asterisk (*) next to a setup item indicates the default (factory) setting.