Datasheet

2
Connections - terminals Screw clamp terminal power circuit 1 1...4 mm² flexi-
ble without
Screw clamp terminal power circuit 2 1...4 mm² flexi-
ble without
Screw clamp terminal power circuit 1 1...4 mm² flexi-
ble with
Screw clamp terminal power circuit 2 1...2,5 mm² fle-
xible with
Screw clamp terminal power circuit 1 1...4 mm² solid
without
Screw clamp terminal power circuit 2 1...4 mm² solid
without
Screw clamp terminal control circuit 1 1...4 mm² fle-
xible without
Screw clamp terminal control circuit 2 1...4 mm² fle-
xible without
Screw clamp terminal control circuit 1 1...4 mm² fle-
xible with
Screw clamp terminal control circuit 2 1...2,5 mm²
flexible with
Screw clamp terminal control circuit 1 1...4 mm² so-
lid without
Screw clamp terminal control circuit 2 1...4 mm² so-
lid without
Complementary
Coil technology Built-in bidirectional peak limiting diode suppressor
Protective cover With
[Ie] rated operational current 9 A ≤ 60 °C AC AC-3 power circuit
25 A ≤ 60 °C AC AC-1 power circuit
Motor power kW 2,2 kW 220...240 V AC 50/60 Hz
4 kW 380...400 V AC 50/60 Hz
4 kW 415 V AC 50/60 Hz
4 kW 440 V AC 50/60 Hz
5,5 kW 500 V AC 50/60 Hz
5,5 kW 660...690 V AC 50/60 Hz
Motor power hp 0,5 hp 115 V 1P AC 60 Hz UL
0,5 hp 115 V 1P AC 60 Hz CSA
1 hp 230/240 V 1P AC 60 Hz UL
1 hp 230/240 V 1P AC 60 Hz CSA
2 hp 230/240 V 3P AC 60 Hz CSA
2 hp 230/240 V 3P AC 60 Hz UL
2 hp 200/208 V 3P AC 60 Hz CSA
2 hp 200/208 V 3P AC 60 Hz UL
5 hp 460/480 V 3P AC 60 Hz CSA
5 hp 460/480 V 3P AC 60 Hz UL
7,5 hp 575/600 V 3P AC 60 Hz CSA
7,5 hp 575/600 V 3P AC 60 Hz UL
Auxiliary contacts type Mechanically linked IEC 60947-5-1 1 NO + 1 NC
Mirror contact IEC 60947-4-1 1 NC
Auxiliary contact composition 1 NO + 1 NC
Control circuit voltage limits 0.1...0.3 Uc ≤ 60 °C drop-out
0.8...1.25 Uc ≤ 60 °C operational
Time constant 40 ms
[Ui] rated insulation voltage 600 V UL power circuit
600 V CSA power circuit
600 V UL control circuit
600 V CSA control circuit
690 V IEC 60947-1 power circuit
690 V IEC 60947-1 control circuit
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Overvoltage category III
Mounting support Plate
Rail
Flame retardance V1 UL 94
Tightening torque 1,7 N.m control circuit screw clamp terminal flat Ø 6 mm
1,7 N.m control circuit screw clamp terminal Philips No 2 2 mm
1,7 N.m power circuit screw clamp terminal flat Ø 6 mm
1,7 N.m power circuit screw clamp terminal Philips No 2 2 mm
[Ue] rated operational voltage <= 690 V AC 25...400 Hz power circuit
[Ith] conventional free air thermal current 10 A ≤ 60 °C control circuit
25 A ≤ 60 °C power circuit