Datasheet

Product datasheet
Characteristics
LC1D18U7TQ
contactor TeSys LC1-
D
- 3 poles -
AC
-3 440V 18 A -
coil 240 V AC
Main
Range of product
TeSys D
Range
TeSys
Product or component type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC
-1
AC
-3
Control circuit type
AC 50/60 Hz
Poles description
3P
Pole contact composition
3 NO
[Ie] rated operational current
18 A (<= 60 °C) at <= 440 V AC AC-3 for power
circuit
32 A (<= 60 °C) at <= 440 V AC AC-1 for power
circuit
Motor power kW
10 kW at 500 V AC 50/60 Hz AC-3
10 kW at 660...690 V AC 50/60 Hz AC-3
4 kW at 220...230 V AC 50/60 Hz AC-3
7.5 kW at 380...400 V AC 50/60 Hz AC-3
9 kW at 415...440 V AC 50/60 Hz AC-3
4 kW at 400 V AC 50/60 Hz AC-4
Motor power hp
1 hp at 115 V AC 50/60 Hz for 1P motors
conforming to CSA
1 hp at 115 V AC 50/60 Hz for 1P motors
conforming to UL
10 hp at 460/480 V AC 50/60 Hz for 3P motors
conforming to CSA
10 hp at 460/480 V AC 50/60 Hz for 3P motors
conforming to UL
15 hp at 575/600 V AC 50/60 Hz for 3P motors
conforming to CSA
15 hp at 575/600 V AC 50/60 Hz for 3P motors
conforming to UL
3 hp at 230...240 V AC 50/60 Hz for 1P motors
conforming to CSA
3 hp at 230...240 V AC 50/60 Hz for 1P motors
conforming to UL
5 hp at 200/208 V AC 50/60 Hz for 3P motors
conforming to CSA
5 hp at 200/208 V AC 50/60 Hz for 3P motors
conforming to UL
5 hp at 230...240 V AC 50/60 Hz for 3P motors
conforming to CSA
5 hp at 230...240 V AC 50/60 Hz for 3P motors
conforming to UL
[Uc] control circuit voltage
240 V AC 50/60 Hz
Connections - terminals
Control circuit : screw clamp terminal 1 cable 1...4
mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminal 2 cable 1...4
mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminal 2 cable 1...4
mm² - cable stiffness: solid - without cable end
Control circuit : spring terminal 1 cable 2.5 mm² -
cable stiffness: flexible - without cable end
Control circuit : spring terminal 2 cable 2.5 mm² -
cable stiffness: flexible - without cable end
Power circuit : screw clamp terminal 1 cable 1...6
mm² - cable stiffness: flexible - with cable end
Power circuit : screw clamp terminal 1 cable
1.5...6 mm² - cable stiffness: flexible - without
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 3

Summary of content (3 pages)