Datasheet

Product datasheet
Characteristics
LC1D40008P7
TeSys D contactor - 4P(2 NO + 2 NC) -
AC
-1 <= 440
V 60 A 230 V AC 50/60 Hz coil
Main
Range
TeSys
Product name
TeSys D
Product or component type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC
-1
Poles description
4P
Pole contact composition
2 NO + 2 NC
[Ue] rated operational voltage
<= 690 V AC 25...400 Hz for power circuit
<= 300 V DC for power circuit
[Ie] rated operational current
60 A (<= 60 °C) at <= 440 V AC AC-1 for power
circuit
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
[Uimp] rated impulse withstand
voltage
Conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal
current
60 A at <= 60 °C for power circuit
Irms rated making capacity
800 A at 440 V for power circuit conforming to IEC
60947
Rated breaking capacity
800 A at 440 V for power circuit conforming to IEC
60947
[Icw] rated short-time withstand
current
320 A <= 40 °C 10 s power circuit
720 A <= 40 °C 1 s power circuit
72 A <= 40 °C 10 min power circuit
165 A <= 40 °C 1 min power circuit
Associated fuse rating
80 A gG at <= 690 V coordination type 1 for power
circuit
80 A gG at <= 690 V coordination type 2 for power
circuit
Average impedance
1.5 mOhm at 50 Hz - Ith 60 A for power circuit
[Ui] rated insulation voltage
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-
1
Electrical durability
1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Power dissipation per pole
5.4 W AC-1
Protective cover
Without
Mounting support
Plate
Rail
Standards
UL 508
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
Product certifications
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 3

Summary of content (3 pages)