Datasheet

Product datasheet
Characteristics
LC1DFKP7
contactor TeSys LC1-DF 12.5 kVAr -
coil 230 V AC
Main
Range
TeSys
Product name
TeSys LC1D.K
Product or component type
Capacitor duty contactor
Device short name
LC1DFK
Device application
Control
Contactor application
Power factor correction
Poles description
3P
Pole contact composition
3 NO
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz for power circuit
Reactive power rating
7 kvar at 220...240 V AC 50/60 Hz <= 55 °C
13 kvar at 400...440 V AC 50/60 Hz <= 55 °C
21 kvar at 660...690 V AC 50/60 Hz <= 55 °C
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 2 NC instantaneous for control circuit
Electrical durability
300000 cycles at Ue 400 V
200000 cycles at Ue 690 V
Mounting support
DIN rail
Plate
Standards
IEC 60947-4-1
Product certifications
CCC
CSA
UL
Connections - terminals
Power circuit : connector 1 cable(s) 2.5 mm² -
cable stiffness: flexible - with cable end
Power circuit : connector 2 cable(s) 1.5 mm² -
cable stiffness: flexible - with cable end
Power circuit : connector 1 cable(s) 4 mm² - cable
stiffness: solid - without cable end
Power circuit : connector 2 cable(s) 4 mm² - cable
stiffness: solid - without cable end
Tightening torque
Power circuit : 1.7 N.m - on connector
Operating rate
240 cyc/h
Complementary
Auxiliary contacts type
Type mechanically linked (1 NO + 2 NC) conforming to IEC 60947-5-1
Environment
IP degree of protection
IP20 conforming to IEC 60529
protective treatment
TH conforming to IEC 60068-2-30
ambient air temperature for operation
-5...60 °C
ambient air temperature for storage
-60...80 °C
operating altitude
3000 m without derating
height
130 mm
width
45 mm
depth
117 mm
product weight
0.53 kg
Offer Sustainability
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 2

Summary of content (2 pages)