Datasheet
Product datasheet
Characteristics
LZ2H2X4BD
Reversing Starter TeSys H 0,75kW-400V control
24VDC
Main
Range
TeSys
Product name
TeSys H
Device short name
LZ2H
Product or component type
Reversing ultra-compact starter
Motor starter type
Direct on line
Poles description
3P
[Ue] rated operational voltage
500 V AC
[Ie] rated operational current
2.4 A at 500 V AC-51
2.4 A at 500 V AC-53A
2.4 A at 500 V AC-51 mounting side by side
2.4 A at 500 V AC-53A mounting side by side
Thermal protection adjustment
range
0.18...2.4 A
Motor power kW
0.37 kW at 220 V AC with power factor : 0.65
0.37 kW at 230 V AC with power factor : 0.65
0.75 kW at 380 V AC with power factor : 0.65
0.75 kW at 400 V AC with power factor : 0.65
0.75 kW at 415 V AC with power factor : 0.65
0.75 kW at 440 V AC with power factor : 0.65
1.1 kW at 500 V AC with power factor : 0.65
Motor power hp
0.5 hp at 200 V AC
0.5 hp at 230 V AC
1 hp at 460 V AC
[Uc] control circuit voltage
24 V DC
Thermal overload class
Class 10A conforming to IEC 60947-4-2
Complementary
Auxiliary contact composition
1 C/O fault signalling
Control circuit voltage limits
19.2...30 V DC
Current consumption
<= 40 mA at 24 V DC
Reset
Automatic reset
Manual
Electrical reset
Electrical durability
30 Mcycles
Operating rate
120 cyc/mn AC-51 50 % ON
6 cyc/mn AC-53A 50 % ON
Mounting mode
By clips
Mounting support
DIN rail
Connections - terminals
Screw clamp terminals 1 cable 0.2...2.5 mm² - cable stiffness: rigid
Screw clamp terminals 1 cable 0.25...2.5 mm² - cable stiffness: flexible - with cable
end
Screw clamp terminals 1 cable 0.2...2.5 mm² - cable stiffness: flexible - without cable
end
Tightening torque
0.5...0.6 N.m - with screwdriver 3 mm flat Ø 2.5 mm
Certifications
CE
CULus
Standards
IEC 60947-4-2
UL 60947-4-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
6 kV
Pollution degree
2
Width
22.5 mm
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 2