Specifications
2/31
Industrial PCs
Magelis
®
Compact PC BOX
Specications
2
Specications of Magelis
®
Compact PC BOX CPUs
Type General Purpose Magelis
®
Compact PC BOX
MPC KN0 2NAX 00N
Hard disk
Processor Intel
®
Celeron
®
M 1 GHz
Storage Hard disk u 80 GB
RAM 512 MB SDRAM, expandable to 1024 MB
Slots for Compact Flash cards 2
Expansion slots 1 PCI 2.2 bus slot
Built-in I/O ports Ethernet ports 1 Ethernet TCP/IP 10/100BASE-T link (RJ45 connector)
1 Ethernet TCP/IP 10/100/1000 BASE-T link (RJ45 connector)
USB 4 USB 2.0 links (at rear)
Serial links 2: COM1, COM2, RS 232 type (9-pin male SUB-D connector)
Video 1 connection for external RGB video screen
Audio 1 audio output for loudspeakers (mini-jack connector)
Floppy disk drive 1
Operating system Windows XP
®
Pro SP2 pre-installed
Compatible screens from the Magelis
®
offer iDisplay
Power supply AC
Voltages a 100...240 V (voltage limits 85...265 V)
Frequency 50/60 Hz (frequency limits 47/63 Hz), conforming to EN 61131-2
Micro-breaks 20 ms max.
Isolation a 1500 V, 20 mA for 1 minute
Consumption 120 VA
PCI expansion
Capacity c
- 5 V, 1.5 A
c
- 12 V, 0.5 A
c
- 12 V, 0.1 A
c
- 3.3 V, 0.5 A
Consumption 10.9 W between 5 °C and 45 °C (ambient air temperature)
Linear decrease to 7.6 W between 45 °C and 50 °C
Material Nickel plated steel
Mounting In enclosure, horizontally or on wall. Supplied with set of 2 xings.
Environmental characteristics of Magelis
®
Compact PC BOX CPUs
Type MPC KN0 2NAX 00N
Degree of protection IP 20
Standards: IEC/EN 60529, NEMA 250, EN 61131-2
Pollution level Designed for use in environments with pollution level 2
Temperature In operation 5 to 50 °C, conforming to EN 61131-2, UL 1604
Storage - 20 to 60 °C, conforming to IEC 60068-2-2 tests Bb and Ab, IEC 60068-2-14 test Na and EN
61131-2
Operating altitude 0...2000 m. Standard EN 61131-2
Vibration resistance In operation 75 mm amplitude from 10 to 57.6 Hz
1 g amplitude from 57.6 to 150 Hz
Standard EN 61131-2
Out of service
(in storage)
3.5 mm amplitude from 5 to 9 Hz
1 g amplitude from 9 to 150 Hz
Standard EN 61131-2
Shock resistance In operation 15 g peak for 11 ms. Standard IEC 60068-2-27 test Ea and EN 61131-2
Humidity 10 to 85% RH
wet-bulb temperature: 29 °C max.-
without condensation-
Immunity to interference High frequency interference Conforming to EN 61131-2, IEC 61000-4-3/6 level 3
Electromagnetic waves Class A/EN 55022/55011
Certications Information Technology
Equipment
IEC/EN 60950
C-Tick, N998
Industrial Control Equipment UL 508, CSA 22.2, n° 142
Description:
page 2/30
References:
page 2/40
Dimensions:
pages 2/46
2
3
4
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com