Specifications
3/15
Magelis
®
HMI software
Vijeo Designer
™
conguration software
Specications (continued)
Specications of Vijeo Designer
™
applications (continued)
Terminal access security
Access to all or some of the objects in Vijeo Designer
™
can be made subject to users proving
that they are in possession of sufcient rights (user name and password).
Type of right Application: pages, buttons with conrmation, etc.-
Data Manager: access via FTP service-
Web Gate: intranet/extranet access (IP address ltering)-
Number of users per group of
rights
Up to 100
Number of groups of rights Up to 20
Automatic locking If active: automatic blocking of access via keyboard if no entries are made for a set period of
time
Target security
Vijeo Designer
™
can increase the condentiality of applications on Magelis
®
Smart HMI edition,
Compact iPC HMI edition and PC BOX by putting protection mechanisms in place at two levels:
BIOS Disabling of startup via peripheral connected to USB port-
Disabling of USB ports-
Password protection for BIOS access-
Run-Time Vijeo Designer
™
Hiding of Windows-
®
taskbar
Disabling of toggling between tasks (ALT+TAB)-
Disabling of Windows Security Manager (CTRL+ALT+DEL), including the Task Manager-
Disabling of Windows shortcuts-
Disabling of the "Windows logo" key on the keyboard-
Disabling of shortcut to exit run time (CTRL+Z) -
Schneider Electric protocols
Vijeo Designer
™
supports Schneider Electric protocols:
Modbus-
®
RTU Master
Modbus TCP/IP Master-
Modbus Plus-
™
(1)
ELAU-
®
PacDrive
®
Uni-Telway-
™
UniTE TCP/IP-
USB terminal port for Modicon-
®
M340
™
CPUs
FIPIO-
®
(5), FIPWAY
®
(5)
All Schneider Electric drivers offer IEC access to input and output
bits/words: Modbus (RTU and TCP/IP), Modbus Plus (GMU and USB), Uni-Telway, Xway
™
.
Direct I/O access authorizes access to hardware input and output registers.
Register addresses comply with the syntax of IEC standards and the address rules for UNITY
™
conguration software (%I, %IW, %Q, %QW).
If requested by the user, the variables associated with a PLC can be read
("on demand scan" function).
The DDT and unlocated variables of Unity
™
Pro are supported.
Third-party protocols
Vijeo Designer
™
also supports the following protocols and PLCs:
Mitsubishi Melsec
®
protocols: A/Q CPU (SIO), A/Q Ethernet (TCP), A Link (SIO), QnA CPU (SIO), Q
Ethernet (UDP), FX (CPU), FX 3U (CPU).
Except for Melsec-A Link (SIO), Mitsubishi serial link protocols do not work on the RJ45 port (1).
Omron Sysmac
®
protocols: FINS (SIO), LINK (SIO), FINS (Ethernet) and Trajexia.
OMRON serial link protocols do not work on the RJ45 port. (2)
Rockwell Automation Allen-Bradley protocols: DF1-Full Duplex, RS DataHighway 485, Ethernet IP (3) (PLC5,
SLC500, MicroLogix, ControlLogix
®
), Ethernet IP native (2) (ControlLogix),
DeviceNet Slave (6)
Siemens Simatic
®
protocols: MPI (S7-300/400), MPI Direct, RK512/3964R (S7-300/400), PPI, Siemens
Ethernet.
The S7-300/400 MPI Adapter and RK512/3964R - RS485 connection serial link protocols do
not work on the RJ45 port. (2)
Probus DP protocol: via XBT ZG PDP (4)
(1) Via USB cable: XBT ZG UMP for XBT GT 2ppp and higher, TSX C USB MBP for Smart and
Compact iPC
(2) They are supported on XBT GT (SUB-D connector, XBT GT2 and higher).
(3) Certied ODVA compatibility
(4) Certied by Probus Foundation
(5) Via the USB FIPIO
®
module: TSX CUSB FIP
(6) Via the DeviceNet module: XBT ZGDVN
2