Specifications
1/14
Operator dialog terminals
Magelis
®
XBT N Small Panels
Magelis
®
Small Panels
Downloadable exchange
protocol
Compatible PLCs Supply voltage Type of screen Reference Weight
kg
Terminal with 2 lines of 20 characters (with alphanumeric screen)
Uni-TE
™
, Modbus
®
Twido
®
, Nano
™
, TSX Micro
™
,
Premium
™
, Modicon
®
M340
™
5 c via PLC
terminal port
Green backlit
LCD
XBTN200 0.360
Terminals with 4 lines of 20 characters (with matrix screen)
Uni-TE, Modbus Twido, Nano, TSX Micro
™
,
Premium, Modicon M340
5 V c via PLC
terminal port
Green backlit
LCD (122 x 32
pixels)
XBTN400 0.360
Twido (1), Nano, TSX Micro,
Premium, TSX series 7,
Momentum
™
, Quantum
™
Other Modbus slave devices,
Modicon M340
24 V c external
supply
Green backlit
LCD (122 x 32
pixels)
XBTN410 0.380
Green, orange
and red backlit
LCD (2) (122 x 32
pixels)
XBTN401 0.380
Modbus
TeSys
®
model U motor
starters (3)
Altivar
®
drives
24 V c external
supply
Green backlit
LCD (122 x 32
pixels)
XBTNU400 0.380
Software
Description Operating system Reference
Conguration software Windows 2000
®
, Windows XP
®
, and Windows Vista
®
See pages
3/7 and 3/17
–
Accessories (4)
Description Details For use with Reference Weight
kg
Flush mounting accessory Kit for applications requiring a higher degree of
dust and damp protection or customization of the
panel, using a at metal strip (not included)
All XBT N XBTZN01 –
Protective sheets 10 peel-off sheets All XBT N XBTZN02 –
Sheets of re-usable labels 10 sheets of 6 labels XBT N200/400 XBLYN00 –
XBT N401 XBT
NU400
XBLYN01 –
Mechanical adaptors for
substitution of XBT H
From XBT H0p2p1/H0p1010 to XBT N410
From XBT H811050 to XBT N410
– XBTZNCO –
Connection cables and accessories (5)
Description Compatibility Types of
connector
Physical
link
Protocol Length Reference Weight
kg
Adaptor cable XBT N200 XBT
N400 (6)
RJ45-RJ45 RS 232C
RS 485
Modbus
®
,
Uni-TE
™
0.1 m XBTZN999 –
Zelio controller cable XBTN401
XBTR411
XBTRT511
Zelio
®
SR2/
SR3
– Zelio
®
Logic 2.5m SR2CBL08 –
(1) Connection via integrated port or optional serial port on the Twido programmable controller.
(2) Also has 4 indicator LEDs.
(3) Factory preloaded application for monitoring, diagnostics and adjustment of 1 to 8 TeSys
model U motor starters.
(4) Other accessories (see page 1/20).
(5) Other connection cables and accessories (see pages 1/20 to 1/23).
(6) Adaptor cable included with new version XBT N200/N400 terminals. The XBT ZN999 adaptor
is for use with new version XBT N200/N400 terminals and the XBT Z978 cable (replaced by
XBT Z9780), or with the old version XBT N200/N400 terminals and the new XBT Z9780
cable.
Note: The new version XBT N terminal can be distinguished externally from the old version as it has
the Schneider Electric logo on the front panel (on the left above the screen).
XBT N200
XBT N400/N410/NU400
XBT N401
ESC DEL
MOD
XBT ZN01
521377
ENTER
ESC DEL
MOD
ENTER
ESC DEL
MOD
XBT ZN02
521373
Introduction:
pages 1/6 to 1/7
Dimensions:
page 1/68
References
2
3
4
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com