Technical information

Ethernet Configuration
72
EIO0000000638 04/2012
The following table briefly explains the different parameters needed for setting up an
Ethernet configuration:
NOTE: For more information on how to configure the Ethernet connection between
your computer and the HMI controller, refer to Vijeo-Designer online help.
Default IP Address
The default IP address is based on MAC address of the device. The first two bytes
are 10 and 10. The last two bytes are the last two bytes of the device’s MAC
address.
The default subnet mask is 255.0.0.0.
NOTE: A MAC address has an hexadecimal format and an IP address has a decimal
format. Convert the MAC address into decimal format.
Example: If the MAC address is 00.80.F4.01.80.F2, the default IP address is
10.10.128.242.
Element Description
Download Choose the project download method you want in the drop down
menu list. When configuring ethernet connection, select Ethernet.
The project download methods are:
z Ethernet
z File System
z USB
z SoMachine
IP Address IP address of the controller.
DHCP When DHCP is:
z Enable: The controller automatically retrieves an IP address
from a DHCP server.
z Disabled: The controller uses a static IP address.
SubnetMask When using a static IP setting, provide the subnet mask of your
network.
DefaultGateway When using a static IP setting, provide the default gateway of your
network.
DNS Enable DNS to use domain names instead of IP addresses.
DNS IP Address When using DNS, provide the IP address for the DNS server.