Data Sheet

Product data sheet
Characteristics
RM35JA32MR
Current control relay 0.15A…15A, 2 C/O
Main
Range of product Zelio Control
Product or component-
type
Modular measurement and control relays
Relay type Current control relay
Relay name RM35JA
Relay monitored para-
meters
Overcurrent or undercurrent detection
Overcurrent or undercurrent in window mode
Time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale val-
ue on crossing the threshold Tt
Switching capacity in-
VA
2000 VA
Measurement range 150 mA...15 A current AC/DC 50/60 Hz
0.15...1.5 A E1-M terminals
0.5...5 A E2-M terminals
1.5...15 A E3-M terminals
Complementary
Reset time <= 1500 ms at maximum voltage
Maximum switching voltage 250 V AC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC
[Us] rated supply voltage 24...240 V AC/DC, 50/60 Hz (+/- 10 %)
Supply voltage limits 20.4...264 V AC/DC
Control circuit voltage limits - 15 % + 10 % Un
Power consumption in VA 3.5 VA AC
Power consumption in W 1.5 W DC
Resistance across terminals 0.005 Ohm at E3-M terminals
0.015 Ohm at E2-M terminals
0.05 Ohm at E1-M terminals
Output contacts 2 C/O
Nominal output current 8 A
Internal input resistance 0.05 Ohm
0.005 Ohm
0.015 Ohm
Setting accuracy of the switching threshold +/- 10 % of the full scale
Switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Setting accuracy of time delay 10 P
Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Hysteresis 5...50 % adjustable of threshold setting for overcurrent or undercurrent detection
3 % fixed of full scale for window mode
Run-up delay at power-up 0.3 s
Measuring cycle 100 ms measurement cycle as true rms value
Repeat accuracy +/- 0.5 % input and measurement circuit
+/- 2 % time delay
Measurement error < 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Response time <= 500 ms on crossing the threshold
Threshold setting 10...100 %
Overvoltage category III conforming to UL 508
III conforming to IEC 60664-1
Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.