Configuration
2–8 975-0560-01-01 Revision B
Configuring the Auxiliary Output
Use the Aux Settings menu item to enable and configure the auxiliary output.
You can use the auxiliary output to operate a relay, indicator light, vent fan, alarm,
or any other required function. See “Auxiliary Output Functions” on page 1–9. For
configurable trigger sources, you can define trigger level, trigger delay, clear
level, and clear delay settings. Non-configurable trigger sources include errors,
warnings, and faults.
Table 2-3 Peak power tracking settings
SCP Device Menu
Item Setting Values Default Description
Advanced Settings >
Input Settings
MPPT AutoTrack Disabled
Enabled
Enabled Enables or disables MPPT.
Advanced Settings >
Input Settings
MPPT Ref Volts 195–600V N/A When tracking is set to
Disabled, you can select the
reference voltage from which the
charge controller operates. When
tracking is set to Enabled, the
reference voltage updates to
reflect tracking activity.
Advanced Settings >
Multi Unit Config >
Connections
PV In SolarArray
1–16
SolarArray1 Sets the input connection for the
charge controller.