Viewing Status on the SCP
975-0560-01-01 Revision B 3–3
Viewing Status on the SCP
Use the SCP to configure and view system information and operating status. See
Appendix B, “Xantrex XW System Control Panel Menus” for an overview of the
SCP, or download the entire SCP Owner’s Guide (Document Part Number
975-0298-01-01) at www.schneider-electric.com. The charge controller also has
three LEDs for displaying basic status regarding charging, equalization, and
fault, error, and warning conditions.
• When in Charge Control mode the SCP displays parameters such as PV
voltage, battery voltage, and charge current on the XW MPPT80 Home
screen.
• When a fault or error condition exists, the SCP Fault/Warning light is solid,
and the SCP shows Fault Active on the XW MPPT80 Home screen.
• When a warning condition exists, the SCP Fault/Warning light is flashing, and
the SCP shows Warning Active on the XW MPPT80 Home screen.
Normal Operation
From the XW MPPT80 Setup screen, select Meters to view normal operation
information. This information is refreshed once per second.
Table 3-2 Normal operation information (Meters screen)
Display Description
PV In Power Measured input power.
PV In Measured input voltage and current.
DC Out Power Power being produced by the charge controller now.
DC Out Measured output voltage and output current.
Time in Float
00:00:00
Elapsed time that the charge controller has been in float in hh:mm:ss format.
Today Accumulated amp hours and kilowatt hours produced today by the charge
controller.
Life Lifetime accumulated amp hours and kilowatt hours produced by the charge
controller.
Batt Temp Battery temperature detected by the BTS. If a BTS is not connected, then no
value is shown.
State Charge stage. See Table 3-3 on page 3–4.
Aux Auxiliary output state. See Table 2-4 on page 2–9.
Thermal Derating Indicates whether the charge controller is derating output power due to high
operating temperatures. See Figure A-4 on page A–6.