Installation Guide
Table Of Contents
- Conext™ SW Inverter Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-01 Revision: Rev A Date: 12-2012
- Contact Information www.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Precautions When Working With Batteries
- Regulatory
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Multiple Unit Configuration
- Generator Support
- Basic Protection Features
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Conext SW AC/DC/Ports Side Panel
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- Gen Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Using the Advanced Features
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Inverter/Charger Operation using the System Control Panel (SCP)
975-0638-01-01 Rev A 3–9
Using the Standby Button
The Standby button has two functions, depending on how it is pressed. First,
when only the Standby button is pressed, it can disable inverting and charging
for all Conext SW units in the system. Second, when it is pressed simultaneously
with the Exit button, this action puts the entire system into Standby mode.
Pressing the Standby button produces the same result as disabling “Invert” and
“AC Charge” from the System Settings menu on the SCP. Pressing the Standby
button momentarily affects only Conext SW units; it does not affect charge
controller operation. After disabling inverting and charging with the Standby
button, the system continues to pass AC input through to the loads.
Pressing the Exit and Standby buttons at the same time puts the entire Xanbus
network system (including charge controllers) into Standby mode. In Standby
mode, the Conext SW stops passing AC input through to the loads.
After the keypress command to enter Standby mode, the AGS – Automatic
Generator Start (if installed) shuts down the generator (if it is running) after a
cool-down cycle.
SCP Navigation
This section describes the different types of screens and menus on the SCP. To
monitor Conext SW operation and change settings, it is helpful to know how to
locate these screens and menus.
Startup Screen
This screen is shown when the SCP first receives power from the Xanbus
network.
Figure 3-1 Startup Screen
Enter Exit
Fault/Warning
Standby
ConextSW-NA-OwnersGuide.book Page 9 Thursday, December 20, 2012 2:00 PM