Installation Guide
Table Of Contents
- Conext™ SW Inverter Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-01 Revision: Rev A Date: 12-2012
- Contact Information www.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Precautions When Working With Batteries
- Regulatory
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Multiple Unit Configuration
- Generator Support
- Basic Protection Features
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Conext SW AC/DC/Ports Side Panel
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- Gen Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Using the Advanced Features
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Viewing the Basic and Advanced Settings Menus
975-0638-01-01 Rev A 4–5
Advanced Settings
menu
The Advanced Settings option gives you access to the full range of Conext SW
settings, including everything displayed on the Basic menu. As a safeguard
against unintended Advanced configuration, the SCP displays the Basic settings
by default. To view the Advanced settings, you must perform a special keypress.
To select the Advanced Settings menu:
1. On the Select Device menu, select a Conext SW device.
2. Press Enter. The Setup menu screen appears.
3. Press Enter + up arrow + down arrow at the same time.
The Conext SW Advanced settings include menus for configuring:
• Inverter settings (see page 4–9).
• Charger settings (see page 4–13).
• AC transfer limit settings (see page 4–20.
• Generator support settings (see page 4–22).
• Multiple unit operation, including customizing the default model name of the
inverter/charger and setting its network device number. Setting the device
number is important when multiple Conext SW units are on the Xanbus
network and sharing connections such as AC loads and AC generator. The
device number is also used when configuring paralleled Conext SW units for
master-slave operation (see page 4–23).
NOTICE
EQUIPMENT DAMAGE
The advanced settings are intended for qualified installation/service personnel
only. Before changing advanced settings, you must be familiar with the
settings and the system-wide impact of changing those settings. Setting
parameters incorrectly could damage connected equipment (such as
batteries) or could severely affect the performance of your system. Incorrect
charging configuration can lead to battery damage.
Failure to follow these instructions can result in equipment damage.
NOTES:
• This keypress (Enter + up arrow + down arrow) enables the Advanced
settings for every device in the system.
• After performing the keypress, “Advanced Settings” appears at the top of
the Setup menu (see Figure 4-2). When the keypress is performed again, the
Setup menu displays “Basic Settings” as the last item on the menu (see
Figure 4-1).