Installation Guide
Table Of Contents
- Conext™ SW Inverter Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-01 Revision: Rev A Date: 12-2012
- Contact Information www.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Precautions When Working With Batteries
- Regulatory
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Multiple Unit Configuration
- Generator Support
- Basic Protection Features
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Conext SW AC/DC/Ports Side Panel
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- Gen Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Using the Advanced Features
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Configuring Advanced Settings
975-0638-01-01 Rev A 4–23
Multi Unit Config Menu
The Multi Unit Config menu configures the Conext SW to operate as a part of
a multiple unit installation
1
.
1.In Conext SW Inverter/Chargers, multiple unit configuration (installation) is limited to two units -
one master unit and one slave unit.
Figure 4-9 Multi Unit Config Menu Screen
CSW4024 00: Adv
Inverter Settings
Charger Settings
AC Settings
Gen Support
Multi Unit Config
Restore Defaults
Adv Features
CSW4024 00: Multi
Dev Name
Dev Number
Invtr Mode
AC In
Battery
[CSW4024]
[00]
[Master]
[Gen1]
[HouseBatt1]
[*Master] [Slave]
[*Gen1] [Grid1]
[*HouseBatt1]...[HouseBatt5]
Follow procedures on “To select and change a configurable setting:” on page 4–6 to
change the settings.
IMPORTANT: Accessing this menu automatically places the Conext SW in
standby mode. When entering the Multi Unit Config menu, the unit identifies
itself by flashing all front panel LEDs. After exiting the Multi Unit Config menu,
the Conext SW returns to operating mode and the front panel LEDs stop flashing.
Table 4-12 Multi Unit Menu Description and Values
a
Item Description Default Range
Dev Name Allows the customizing
of the default name for
the inverter/charger.
This setting is optional
and does not affect
operation. See “Setting
the Device Name” on
page 4–25.
CSW4024
will vary from model
to model.
Can be
changed by
the user.
Dev Number Allows setting of a
unique unit number in a
multiple-unit system.
See “Setting the Device
Number” on page 4–26.
00 usually for a
single unit or for two
units, this will
designate the
master.
00
–31
ConextSW-NA-OwnersGuide.book Page 23 Thursday, December 20, 2012 2:00 PM