Installation Guide
Table Of Contents
- Conextâ„¢ SW Inverter Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-01 Revision: Rev A Date: 12-2012
- Contact Information www.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Precautions When Working With Batteries
- Regulatory
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Multiple Unit Configuration
- Generator Support
- Basic Protection Features
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Conext SW AC/DC/Ports Side Panel
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- Gen Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Using the Advanced Features
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Configuration via SCP
4–24 975-0638-01-01 Rev A
When installing a multiple unit system, every setting on the Multi Unit Config
menu (except for Dev Name) must be configured for each of the two Conext SW
units in the system. The settings should be configured in the following order: Dev
Number then Invtr Mode.
AC In setting The Conext SW accepts only a single AC source - either from the grid or from a
generator. In a power system where the Conext SW is solely connected to the
grid and an AGS is neither present nor required, the AC In setting can be either
Gen1 or Grid1. Therefore, the default value of Gen1 need not be changed.
In a situation where the AC source is a generator and the AGS is being used to
start the generator to produce AC power, the AC In setting must be set to Gen1.
Therefore, the default value of Gen1 must remain unchanged.
In a power system where the two AC sources are available but only one AC
source can be used, an external transfer switch becomes necessary. When an
external transfer switch is used and an AGS (with a B+ signal connection) is also
present, change the AC In setting to Grid1.
Invtr Mode For this to operate, one
Conext SW must be
configured to Master
and the other as Slave,
otherwise a system-wide
fault is asserted.
Master Master,
Slave
AC In For identifying the type
of AC source when two
power sources are
available and an AGS is
also present.
Gen1 Gen1, Grid1
Battery For identifying batteries
only.
HouseBatt1 HouseBatt1..
HouseBatt5
a.Applies to all Conext SW models.
Table 4-12 Multi Unit Menu Description and Values
a
Item Description Default Range
ConextSW-NA-OwnersGuide.book Page 24 Thursday, December 20, 2012 2:00 PM