Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
Xanbus Network Installation
4–2 975-0239-01-01 Rev G
This manual is for use by qualified personnel only
The Xanbus Network
A Xanbus network is a collection of Xanbus enabled devices that perform
individual functions, but also communicate and interact with other devices on the
network. The network capability of the Conext XW+ provides a solution that
simplifies and automates the installation, configuration, control, monitoring, and
integration of devices.
Network Components
A Xanbus network consists of three elements: Xanbus-enabled devices, Xanbus
power supply, and Xanbus cables.
Each device is integrated into the network using cables, network connectors,
and terminators. An example of a network system is shown in Figure 4-1.
NOTICE
SHORT CIRCUIT OF NETWORK COMPONENTS
• This network is not an ethernet system. Only connect Xanbus-enabled
devices to other Xanbus-enabled devices. Do not attempt to connect
Xanbus-enabled devices to other networks or systems.
• Ethernet crossover cables are not compatible with the Xanbus system. Use
Category 5 (CAT 5 or CAT 5e) cables to connect Xanbus-enabled devices.
• Do not install network terminators in an AC Sync port.
Failure to follow these instructions can result in damage to equipment.
Figure 4-1 Xanbus Network System (Example)
Standby
Event/Warning
Conext XW SCP
AC1
AC2
Event
Equalize
kW
A
Charging
!
Inverting
Conext MPPT
Solar Charge
Controllers
Conext XW+
Inverter/Charger
Conext Automatic
Generator Start
Conext System
Control Panel
Network
terminator
Network
terminator