Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
The Xanbus Network
975-0239-01-01 Rev G 4–3
This manual is for use by qualified personnel only
Xanbus-enabled devices
A Xanbus-enabled device is any product that works on a Xanbus network. Below
are some examples of Xanbus-enabled devices:
• Conext System Control Panel
• Conext XW+ Inverter/Charger
• Conext Automatic Generator Start
• Conext Battery Monitor
• MPPT 60 150 Solar Charge Controller
• MPPT 80 600 Solar Charge Controller
Due to network traffic, the maximum number of Conext XW+ units in a single
Xanbus network should not exceed twelve. The maximum number of Conext
MPPT Solar Charge Controllers in a single Xanbus network should not exceed
twelve.
The combined maximum number of Conext XW+ units and Conext MPPT Solar
Charge Controllers should not exceed twelve.
Xanbus power supply
Xanbus-enabled devices are either power-supplying or power-consuming. The
Xanbus network needs at least one device with a power supply sufficient to run
the entire network.
For example, in a system with an Conext XW+ Inverter/Charger, Conext System
Control Panel, and Conext Automatic Generator Start, the Conext XW+ is a
power-supplying device capable of providing 800 mA at 15 VDC while the two
other devices each consume a maximum of 200 mA for a total maximum
consumption of 400 mA. In this example, the network is properly configured from
a power perspective because the power source is capable of providing more
current than is needed: 800 mA 400 mA.
Note: The total network current supplied by the power-sourcing devices must be
equal to or greater than the total current drawn by the power-consuming devices.
The power supply must be capable of providing 15 VDC/200 mA to each device.
Note: See the specifications for each Xanbus-enabled device to determine how
much power each device consumes or supplies.