Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
Specifications
A–2 975-0240-01-01
Electrical Specifications
Table A-1 Conext XW+ Inverter/Charger Electrical Specifications
Conext XW+ 6848 NA Conext XW+ 5548 NA
Continuous Output Power 6,800 W 5,500 W
Surge Rating (Overload for 1 minute) 12,000 W 9,500 W
Surge Rating (Overload for 5 minutes) 11,000 W 9,000 W
Surge Rating (Overload for 30 minutes) 8,500 W 7,000 W
Surge Current
L-N: 104 A
rms
(60 s)
L-L: 52 A
rms
(60 s)
L-N: 82 A
rms
(60 s)
L-L: 41 A
rms
(60 s)
Waveform True Sine Wave
Idle Consumption—Inverter mode, no load 28 W 26 W
Idle Consumption—Search mode < 8 W
AC Output Voltage L-N: 120 VAC ±3%
L-L: 240 VAC ±3%
AC Input Voltage range
(Bypass/Charger Mode)
L-N: 78–140 VAC (120 V nominal)
L-L: 160–270 VAC (240 V nominal)
AC Input Breaker 60 A double-pole
AC Input Frequency Range
(Bypass/Charger Mode)
52–68 Hz (default)
44–70 Hz (allowable)
AC1 voltage range–Sell Mode
a
L-N: 105.6–132 ±1.5 V
L-L: 211–264 ±3.0 V
AC1 frequency range–Sell Mode
a
59.4–60.4 ±0.05 Hz
AC Output Current (maximum 75%
imbalance between L1-N, L2-N) in Inverter
Mode
L-N: 48 A
L-L: 28 A
L-N: 46 A
L-L: 23 A
AC Output Breaker 60 A double-pole
AC Output Frequency 60.0 ±0.1 Hz
Total Harmonic Distortion < 5% at rated power
Automatic Transfer Relay 60 A
Auxiliary Relay Output 0–12 VDC, maximum 250 mA DC
Peak Efficiency 95.7% 95.7%
CEC Weighted Efficiency 92.5% 93.0%
CEC Power Rating
6,000 W
b
5,760 W
c
4,400 W
DC Input Voltage (Nominal) 48 VDC
DC Input Voltage Range 40–64 VDC 40–64 VDC
DC Current at Rated Continuous Power
(Inverter Mode)
180 A 150 A
Continuous Charge Rate at L-L voltage
(Charger Mode)
140 A 110 A