Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
Specifications
A–10 975-0240-01-01
Mechanical Specifications
Table A-2 Conext XW+ Inverter/Charger Mechanical Specifications
Model Conext XW+ 6848 NA Conext XW+ 5548 NA
Supported Battery Types Flooded (default), Gel, AGM, Lithium Ion, Custom
Battery bank size 440–10000 Ah
Non-Volatile Memory Yes
Inverter Information Panel
Status LEDs indicate AC In status, faults/warnings, equalize
mode, battery level. 3-character display indicates output power or
charge current, fault/warning codes. STARTUP/SHUTDOWN and
equalize button
Multiple Unit Configurations
Clusters of up to 3 parallel units in 120/240 three-wire, single-
phase configuration. Up to 4 clusters possible using multi-cluster
for a total of 12 units when using an external AC contactor.
System Network
Conext Xanbus™ (publish-subscribe network, no need for hubs
or special cards)
Emissions FCC Part 15, Class B Industry Canada ICES-003 Issue 5,
Class B
Regulatory approvals CSA C22.2 No. 107.1-01 - General Use Power Supplies
UL 1741 - 2nd Ed - Inverters, Converters, Controllers and
Interconnection System Equipment
Enclosure Type NEMA Type 1—Indoor
Rated Temperature Range
(meets specifications)
32–77 °F (0–25 °C)
Operational Temperature Range -13–158 °F (-25–70 °C)
Storage Temperature Range -40–185 °F (-40–85 °C)
Inverter Dimensions (H×W×D)
23 × 16 × 9" (580 × 410 × 230 mm)
Shipping Dimensions (H×W×D)
28×22½×15½”(711 × 572 × 394 mm)
Inverter Weight 125 lb (57 kg) 115 lb (52 kg)