Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
B–4 975-0239-01-01 Rev G
This manual is for use by qualified personnel only
Single-Inverter System (Backup Only) With a Conext XW+ Power Distribution Panel
Figure B-2 Single-Inverter System (Backup Only) With a Conext XW+ Power Distribution Panel
NL1L2NL1L2NL1 L2
AC IN
GRID
(AC1)
AC OUT
INV
OUT
AC IN
GEN
(AC2)
Standby
Event/Warning
Conext XW SCP
NG
L1 L2
L2
L1
1
2
3 4
1
2 4
5 7
8
3
6
5
7
6
8
8
SCP (optional) AGS (optional)
Main utility panel
Inverter load sub-panel
AC generator
Generator disconnect
AC Sync cable
Ground
Xanbus cable
Hot L1
Hot L2
Neutral
DC disconnect
LEGEND
AC breakers
Network ter minator
Battery bank
Positive (+)
battery terminal
Negative (-)
battery terminal
Actual wiring requirements may vary.
Cable routing may vary.
See Knockout Selection on page 2-5 and Communications Network Preparation on page
2-12.
For torque values, see page 2-16 and 2-17.
For torque connections to the battery terminals, consult the battery manufacturer’s
recommendations.
Positive (+)
battery cable
Negative (-)
battery cable
BTS cable