Installation Guide
Table Of Contents
- Conext™ XW+ Inverter/Charger Installation Guide
- Conext™ XW+ Inverter/Charger Installation Guide
- About This Guide
- Important Safety Instructions
- Contents
- Introduction
- Overview
- Optional Accessories
- Conext XW+ Conduit Box
- Conext XW+ Power Distribution Panel
- Conext XW+ Connection Kit for INV2 INV3 PDP
- Conext 120/240VAC Breaker Kit for Conext XW+ PDP
- Conext MPPT 60 150 Solar Charge Controller
- Conext MPPT 80 600 Solar Charge Controller
- Conext System Control Panel
- Conext Automatic Generator Start
- Conext ComBox
- Conext Battery Monitor
- Conext 3 Phase Breaker Kit for Conext XW+ PDP
- 100A, 125VDC Breaker Master Pack (12 units)
- 80A, 125VDC Breaker Master Pack (12 units)
- 60A, 160VDC Breaker Master Pack (48 units)
- 250A, 160VDC Breaker Master Pack (6 units)
- Pre-Installation and Wall-Mounting
- Wiring the Conext XW+ Inverter/ Charger and Conext XW+ Power Distribution Panel
- Removing the AC Access Panel and PDP Internal Faceplates
- Communication Ports and BTS Port
- Wiring the Conext XW+ Inverter/Charger with a PDP
- Basic Functional Test – Single Inverter
- Wiring Additional Conext XW+ units with a PDP
- Basic Functional Test - Multiple Inverters
- Wiring a Balanced Three-Phase System
- Wiring the Conext XW+ Inverter/Charger without a PDP
- Xanbus Network Installation
- Conext XW+ Inverter/Charger Accessories Installation
- Specifications
- Wiring Diagrams
- Split-Phase to Single-Phase Conversion Instructions
Pre-Installation and Wall-Mounting
2–8 975-0239-01-01 Rev G
This manual is for use by qualified personnel only
Installing the Mounting Plate
To install the mounting plate:
1. Locate the wall studs.
2. If necessary, secure a ¾" plywood panel or other appropriate additional
support panel to the wall studs. The additional support panel must span at
least three wall studs.
3. Using a level, secure the first mounting bracket to the wall. Ensure the
mounting plate is centered on the wall studs, as shown in Figure 2-5. Use
recommended anchoring hardware to secure the plate (see Table 2-1).
Installation tip If you install the bottom of the mounting plate at 60" (152 cm) from floor, the
inverter information panel will be approximately 65" from the floor.
4. Install additional mounting plates adjacent to each other as needed.
Note: To secure the additional support panel to the wall, use hardware sized to
support a minimum of 500 lbs. (227 kg). (Hardware not included.)
Figure 2-5 Mounting plate centered on wall studs
Plywood support panel
2" x 4" wall studs
Wallboard
(optional)
Mounting plate
Note: The mounting plates are designed to interlock (as shown in Figure 2-5, so
that multiple plates can be installed without additional measuring or leveling.