Data Sheet

Product data sheet
Characteristics
RXG21P7
interface plug-in relay - Zelio RXG - 2 C/O
standard - 230V AC - 5A - with LTB
Main
Range of product Zelio Relay
Series name Interface relay
Product or component-
type
Plug-in relay
Device short name RXG
Contacts type and com-
position
2 C/O
Complementary
Status LED Without
Contacts material Silver alloy (AgSnO2In2O3)
Contact resistance 100 mOhm
[Ithe] conventional enclosed thermal current 5 A (temperature : -40...55 °C)
[Ie] rated operational current 5 A at 30 V DC conforming to UL
5 A at 30 V DC conforming to IEC
5 A at 250 V AC conforming to IEC
5 A at 250 V AC conforming to UL
Maximum switching voltage 250 V AC
30 V DC
Load current 5 A at 250 V AC
Maximum switching capacity 1250 VA
Minimum switching capacity 50 mW at 10 mA, 5 V DC
Operating rate <= 18000 cycles/hour no-load
<= 1800 cycles/hour under load
Utilisation coefficient 20 %
Mechanical durability 10000000 cycles
Electrical durability 100000 cycles for NO resistive load at 55 °C
100000 cycles for NC resistive load at 55 °C
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to UL
300 V conforming to CSA
[Uimp] rated impulse withstand voltage 6 kV for 1.2/50 µs
Dielectric strength 5000 V AC (reinforced insulation between coil and contact)
3000 V AC (basic insulation between poles)
1000 V AC (micro disconnection between contacts)
Resistance 23500 Ohm +/- 15 %
Insulation resistance 1000 MOhm at 500 V DC
Mounting position Any position
Average consumption 0.82 VA at 60 Hz
Drop-out voltage threshold >= 0.3 Uc AC
Control circuit voltage limits 0.8...1.1 Uc, AC
Electrical insulation class Class F
Operating time 20 ms
Reset time 20 ms
[Uc] control circuit voltage 230 V AC
Safety reliability data B10d = 100000
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Jun 15, 2018
1

Summary of content (2 pages)