24 Drive for stepper motors
3 Technical Data SD315O
0098441113480, V2.00, 03.2011
3.4 Technical data accessories
3.4.1 Cables
Cable specifications CN1
Cable specifications CN2
Cable specifications CN3
Cable specifications CN4
Shield: Depends on EMC limit values, see
chapter 3.1 "Ambient conditions".
Twisted Pair: Not required
PELV: Required
Minimum conductor cross section: Use a conductor with a sufficient cross
section according to the upstream
fuse and the cable length.
Maximum cable length: -
Shield: Required
Twisted Pair: Required
PELV: Required
Minimum conductor cross section: 0.2 mm
2
(AWG 24)
Maximum cable length: -
Shield: Depends on EMC limit values, see
chapter 3.1 "Ambient conditions".
Twisted Pair: Not required
PELV: Required
Minimum conductor cross section: 0.75 mm
2
.
Use a conductor with a sufficient cross
section according to the upstream
fuse and the cable length.
Maximum cable length: 50 m
Shield: Required
Twisted Pair: Required
PELV: Required
Minimum conductor cross section: 0.2 mm
2
(AWG 24)
Maximum cable length: -