4.3 Electrical installation
Suitability of the cables Cables must not be twisted, stretched, crushed or bent. Use only cables
that comply with the cable specification. Consider the following in deter-
mining suitability of the cables:
Suitable for drag chain applications
Temperature range
Chemical resistance
Outdoor installation
Underground installation
4.3.1 Overview of procedure
Connect the housing to the central ground point of the system.
Verify compliance with the EMC requirements, see page 30.
Finally, verify proper installation.
@ WARNING
UNEXPECTED BEHAVIOR DUE TO EXTERNAL OBJECTS
External objects, deposits or humidity can cause unexpected behav-
ior.
Do not use damaged products.
Prevent external objects such as chips, screws or wire clippings
from entering the product.
Do not use products that contain external objects.
Failure to follow these instructions can result in death, serious
injury or equipment damage.
Chapter Page
4.3.3 "Connecting the power stage supply (CN1)" 38
4.3.4 "Connecting the signal interface (CN2)" 41
4.3.5 "Connecting the motor phases (CN3)" 44
4.3.6 "Connecting the signal interface (CN4)" 47