SD315O 4 Installation
Drive for stepper motors 43
Cable specifications
Properties of the connector The connector is available as a part of a connector kit. See chapter 9
"Accessories and spare parts".
The terminals are approved for fine wire conductors and rigid conduc-
tors. Observe the maximum permissible connection cross section. Take
into account the fact that wire ferrules increase the conductor cross sec-
tion.
Shield: Required
Twisted Pair: Required
PELV: Required
Minimum conductor cross section: 0.2 mm
2
(AWG 24)
Maximum cable length: -
Designation Spring force connector, 11 pins
Type FK-MCP 1,5/11-ST-3,81
(Phoenix Combicon)
Maximum connection cross sec-
tion with wire ferrule without plastic
collar
[mm
2
] 1.5 (AWG 16)
Maximum connection cross sec-
tion with wire ferrule with plastic
collar
[mm
2
] 0.5 (AWG 22)
Stripping length [mm] 9