SD315O 4 Installation
Drive for stepper motors 45
Assembling cables
Figure 4.9 Assembling motor cables
(A) 70 mm
(B) 60 mm
Cable specifications
Connection Meaning Color
1)
1) Color information relates to the cables available as accessories.
U Motor phase Brown (BN)
V Motor phase Blue (BU)
W Motor phase Black (BK)
Ground Ground Green/yellow (GN/YE)
BN
BU
BK
GN/YE
A
1
2
BN BU BK
GN/YE
B
A
3
50
20
Shield: Depends on EMC limit values, see
chapter 3.1 "Ambient conditions".
Twisted Pair: Not required
PELV: Required
Minimum conductor cross section: 0.75 mm
2
.
Use a conductor with a sufficient cross
section according to the upstream
fuse and the cable length.
Maximum cable length: 50 m