50 Drive for stepper motors
4 Installation SD315O
0098441113480, V2.00, 03.2011
Properties of the connector The connector is available as a part of a connector kit. See chapter 9
"Accessories and spare parts".
The terminals are approved for fine wire conductors and rigid conduc-
tors. Observe the maximum permissible connection cross section. Take
into account the fact that wire ferrules increase the conductor cross sec-
tion.
4.4 Checking installation
Verify proper installation:
Did you properly install and connect all cables and connectors?
Are there any live, exposed cables?
Did you properly connect the signal wires?
Are all fuses correct?
Designation Spring force connector, 12 pins
Type FK-MCP 1,5/12-ST-3,81
(Phoenix Combicon)
Maximum connection cross sec-
tion with wire ferrule without plastic
collar
[mm
2
] 1.5 (AWG 16)
Maximum connection cross sec-
tion with wire ferrule with plastic
collar
[mm
2
] 0.5 (AWG 22)
Stripping length [mm] 9