52 Drive for stepper motors
5 Commissioning SD315O
0098441113480, V2.00, 03.2011
5.1 Overview
You must also re-commission an already configured
product if you want to use it under changed operating
conditions.
To be done
@ WARNING
UNINTENDED BEHAVIOR
Unsuitable settings or unsuitable data may trigger unexpected move-
ments, trigger signals, damage parts and disable monitoring func-
tions.
• Do not operate the drive system with unknown settings or data.
• Verify that the stored data and settings are correct.
• When commissioning, carefully run tests for all operating states
and potential error situations.
• Verify the functions after replacing the product and also after
making changes to the settings or data.
• Only start the system if there are no persons or obstructions in
the hazardous area.
Failure to follow these instructions can result in death, serious
injury or equipment damage.
@ WARNING
HOT SURFACES
The heat sink at the product may heat up to over 100°C (212°F) during
operation.
• Avoid contact with the hot heat sink.
• Do not allow flammable or heat-sensitive parts in the immediate
vicinity.
• Consider the measures for heat dissipation described.
Failure to follow these instructions can result in death or serious
injury.
Chapter Page
4.4 "Checking installation" 50
5.2.2 "Setting the nominal current" 54
5.2.3 "Setting the current reduction" 55
5.2.4 "Setting the Softstep function" 56
5.2.5 "Setting the number of steps" 57
5.2.6 "Setting the type of Enable" 58
5.2.7 "Setting the source for the oscillator" 58
5.2.8 "Test run of the drive" 59