0098441113480, V2.00, 03.2011
SD315O 5 Commissioning
Drive for stepper motors 59
5.2.8 Test run of the drive
Function test 쮿 The type of Enable must be set to "ENABLE".
No signal may yet be available at the input ENABLE.
왘 Switch on the supply voltages.
왘 Check the status indication, see chapter 8.1 "Status indication via
LEDs".
컅 LED OK (green) flashes: Device is in the state "Disable".
왘 Enable the power stage via the input ENABLE.
컅 LED OK (green) is steady on.
Output ACTIVE_OUT signals readiness.
왘 Start the first test with a low frequency of the P/D signals. If the sig-
nal DIR has 0 level, the motor must perform a movement in positive
direction.
왘 Also perform movements with reversed direction of movement. A
reversal of the active edge at the signal input PULSE can cause dis-
placement of the position when the direction is reversed.
The motor must follow the reference values correctly.
Temperature test The maximum temperature of the motor must not be exceeded. The
temperature of the motor is not monitored by the drive.
왘 Perform a test of the motor under realistic conditions.
왘 Check the temperature of the motor.