SD315O 11 Extract
Drive for stepper motors 85
11.2.5 Setting the type of Enable
Parameter switch S3.4 allows you to set the type of Enable.
See chapter 6.2 "Enabling motor movements" for a description of the
function.
Switch off all supply voltages. Verify that no voltages are present
(safety instructions).
Use parameter switch S3.4 to set the function to "ENABLE" or
"GATE".
11.2.6 Setting the source for the oscillator
Parameter switch S4.1 allows you to set the source for the oscillator.
See chapter 6 "Operation" for a description of the function.
Switch off all supply voltages. Verify that no voltages are present
(safety instructions).
Use parameter switch S4.1 to set the source for the oscillator.
Switch setting S3.4 Meaning
OFF (factory setting) Function "ENABLE"
Enabling and disabling the power stage
ON Function "GATE"
Blocking and enabling P/D signals
Switch setting S4.1 Meaning
OFF (factory setting) Velocity, acceleration ramp and deceleration
ramp are set via the integrated potentiometers.
See chapter 6.3.1 "Reference values via the dig-
ital signal inputs".
ON Velocity, acceleration ramp and deceleration
ramp are set via the voltage value at the analog
signal input.
See chapter 6.3.2 "Reference values via the ana-
log signal input".