Powerlink™ Lighting
Control Systems
Class 1210
G3 NF Panelboards 240 V and 480 Y/277 V Factory
Assembled Systems
Maximum Voltage 480 Y/277 Vac
NOTE: Powerlink EM option BCPM list price adder.
a HL and JL frame circuit breakers are also available as main circuit breakers.
b Backfed Main Circuit Breaker—54 circuit only.
c Copper Bus Only.
d For N2 protocol, add $3819.
e Contact your nearest Square D/Schneider Electric sales office for MICROLOGIC™ trip
main circuit breakers
Note: All EC, ED, EG and EJ branch circuit breakers are UL Listed as HACR type.
Sub-Feed Circuit Breaker
•
Available on 1
Ø
or 3
Ø
, 125
–
800 A main lugs or 125
–
600 A main circuit breaker
interiors
•
One sub-feed JD, JG, JJ or JL circuit breaker per 250 A panelboard
•
Two sub-feed JD, JG, JJ or JL circuit breakers per 400 A panelboardf
f LC and JJ may not be combined.
g JJ and LC sub-feed circuit breakers cannot be used together.
h Dimensions also for 400 A LC/LI main circuit breaker panels.
i 600 A main lug panelboards require an 8" deep, 26” wide box.
j 600 A main lug panelboards require an 8.75" deep box.
k 800 A main lug panelboards require an 8.75” deep, 26” wide box.
To obtain pricing for the following Special Features please refer to the
Supplemental Digest.
•
PowerLogic™ metering
•
Customer equipment space
•
Increased box depth
•
Box extensions top, bottom and side
•
Drip hoods
•
Non-standard paint
•
NEMA 1 gasketed
•
NEMA 4 Stainless steel enclosure
•
NEMA 4X Fiberglass enclosure (NQOD and NF)
•
Stainless steel trim front (NQOD, NF and I-LINE)
•
Padlockable hasp
•
Special locks (Corbin, Yale, Best)
•
Equal height boxes
•
Common trip to cover two equal height boxes
•
Panelboard skirthides conduits feeding a panelboard
•
Panelboard wireway for terminating conduit in wireway endwall
•
Panelboard interiors and special fronts to fit existing boxes
Table 5.57: Powerlink G3 System Price
List
System Type
30 ckt Interior 42 ckt Interior 54 ckt Interior
12 ckt
bus
24 ckt
bus
18 ckt
bus
36 ckt
bus
21 ckt
bus
42 ckt
bus
Slave Panel 1650.00 3450.00 2025.00 4200.00 2370.00 4890.00
NF500G3 6753.00 8553.00 7128.00 9303.00 7473.00 10143.00
NF1000G3d 10728.00 12528.00 11103.00 13278.00 11448.00 14118.00
NF2000G3 17298.00 19098.00 17673.00 19848.00 18018.00 20688.00
NF3000G3 21072.00 22872.00 21447.00 23622.00 21792.00 24462.00
Table 5.58: Panelboard Base Price (including solid neutral)
Mains
Rating
Main Lugs
Main Circuit Breaker (Circuit Breaker Interrupting Rating—6-2 through 6-8)ae
Standard IC HIC Extra HIC I-Limiter™
2-pole 3-pole
Circuit
Bkr.
2-pole 3-pole
Circuit
Bkr.
2-pole 3-pole
Circuit
Bkr.
2-pole 3-pole
Circuit
Bkr.
2-pole 3-pole
100 A — — EDb 2454.00 2823.00 EGb 3150.00 3624.00 HJ 4872.00 5397.00 FI 6375.00 7326.00
125 A 1269.00 1458.00 EDb 5058.00 5643.00 EGb 6486.00 7464.00 — —— ———
150 A — — HD 4905.00 5430.00 HG 6072.00 6597.00 HJ 6105.00 6630.00 ———
225 A — — JD 6180.00 6570.00 JG 7605.00 8100.00 JJ 9930.00 10995.00 KI 10899.00 12528.00
250 A 1503.00 1728.00 JD 6750.00 7710.00 JG 8985.00 9270.00 JJ 10785.00 12675.00 KI 13731.00 15783.00
400 A 1989.00 2286.00 LA 7995.00 9189.00 LH 11568.00 13296.00 LC 12759.00 14664.00 LI 14025.00 16119.00
600 Ac 3549.00 3933.00 ——————LC 14331.00 16326.00 LI 20460.00 23517.00
800 Ac 5325.00 5850.00 —————— ——————
Table 5.59: Branch Circuit Breaker – Price Per Circuit Breaker
Powerlink G3—ECB Bolt-On
65 kA AIR@240 Vac,
14 kA AIR@480 Y/277
Standard Breakers—EDB Bolt-On
18 kA AIR 1-pole,
25 kA AIR 2 & 3-pole @ 240 V,
18 kA AIR@480 Y/277
Standard Breakers HIC—EGB Bolt-On
65 kA AIR@240 Vac,
35 kA AIR@480 Y/277
Standard Breakers Extra HIC—EJB Bolt-On
100 kA AIR@240 Vac,
65 kA AIR@480 Y/277
Voltage
Ampere
Rating
1-pole 2-pole 3-pole Voltage
Ampere
Rating
1-pole 2-pole 3-pole Voltage
Ampere
Rating
1-pole 2-pole 3-pole Voltage
Ampere
Rating
1-pole 2-pole 3-pole
240
Vac
15–20 438. 1215. 1929.
480Y/
277
Vac
15–60 288. 663. 1122.
480Y/
277
Vac
15–60 486. 1119. 1896.
480Y/
277
Vac
15–60 777. 1767. 3036.
30 438. 1215. 1929. 70 513. 1308. 1569. 70 867. 2211. 2565. 70 1386. 3540. 4245.
480Y/277
Vac
15–20 438. 1215. 1929. 80–100 — 1308. 1569. 80–100 — 2211. 2655. 80–100 — 3540. 4245.
30 438. 1215. — 110–125 — 3825. 4845. 110–125 — 6171. 7131. 110–125 — 7950. 9450.
Space Only 63. 126. 189. Space Only 63.126.189. Space Only 63. 126. 189. Space Only 63. 126. 189.
Table 5.60: Sub-Feed Circuit Breaker (150
–
400 A)
No. of Poles JD JG JJg JL LA LH LCg Space
2 2265.00 3165.00 3844.50 4230.00 2985.00 4150.50 6475.50 619.50
3 2527.50 3825.00 4665.00 5296.50 3687.00 4882.50 7617.00 619.50
Table 5.61: Sub-Feed Breaker Cabinet Data
Max. No. of
Branch Spaces (Does
not include sub-feed
breaker spaces)
Box Height (20" W x 5.75" D)
250 A 400 A LA/LH 600 A 800 A
Main
Lugs
Main
Circuit
Breaker
Main
Lugs
Main
Circuit
Breaker
Main
Lugsj
Main
Circuit
Breaker
i
Main
Lugsk
30 56 68 68 80 68 80h 68
42 62 74 74 86 74 86h 74
54 68 80 80 92 80 92h 80
PE-1
Discount
Schedule