SPECIFICATIONS
Table 3: Specifications – Matrix Switcher
Parameter Description
Supply Voltage 120 Vac
Mains frequency range 47 to 53 Hz and 57 to 63 Hz
Power consumption 220 VA maximum
C-Bus network voltage 15 to 36 Vdc
C-Bus sink current 22 mA; the matrix switcher does not supply current
to the network
C-Bus AC input impedance
80 k @ 1 kHz
Network clock and burden Software selectable
Source input signal level
2.8 V p-p maximum (47 k )
A/D conversion 16 bit PCM
Operating temperature 10 to 40 °C (50 to 104 °F)
Operating humidity 10 to 90% RH (non-condensing)
Table 4: System Audio Output Specifications
Parameter Description
Frequency response 40 Hz to 20 kHz (+2.4 dB / -0.75 dB)
Total harmonic distortion
(1 kHz, 20 W RMS into 4 )
0.16% at 1 kHz, 20 W RMS into 4 ohms
Signal to noise ratio > 63 db (peak, unweighted)
STANDARDS
The Matrix Switcher complies with the following Standards:
Table 5: U.S. and Canadian Product Safety Standards and U.S.
FCC Regulations
Standards/Regulations Title
CSA C22.2 No.
205
Signal Equipment
UL60065 Video and Similar Electronic Apparatus
FCC Part 15 Class B Digital Device for Home or Office Use