Technical information

Catalog Number Description Blank Catalog Number Toggle Catalog Number Description
4-468%6* *WPSZ 4-4181%#8 4-4181%58 8IJUF
4-468%68 8IJUF 4-4181%#* 4-4181%5* *WPSZ
4-468%6- -JHIU"MNPOE 4-4181%#( 4-4181%5( (SBZ
4-468%6( (SBZ 4-4181%#- 4-4181%5- -JHIU"MNPOE
4-468%6# #MBDL 4-4181%## 4-4181%5#  #MBDL
Technical Information
Input 7BD)[
0VUQVU 7BD 7BD
8NBYUVOHTUFO
incandescent load
IQNBYNPUPSMPBE7BD
7"NBYCBMMBTUMPBE 7"NBYCBMMBTUMPBE
0QFSBUJOH5FNQFSBUVSF ¡'¡$
)VNJEJUZ 3)/PODPOEFOTJOH
5JNF%FMBZ"EKVTUNFOU
/PSNBM NJOVUFT
8BML5ISPVHI.PEF NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET
5FTU.PEF TFDPOET
-JHIU-FWFMBEKVTUNFOU '$
%FUFDUJPO ¡QBTTJWFJOGSBSFE1*3
"VEJCMF"MFSU 4FMFDUBCMF
4FSWJDF4XJUDI 0''"VUP0/
.BOVBM0QFSBUJPO 1VTICVUUPO0/0''
-FOT *NQBDU3FTJTUBOU
3FMBZ4XJUDIJOH ¡V4
4UBOEBSET 6-BOED6--JTUFE'$$1BSU
)PNFBOE0GýDF6TF$MBTT#5JUMF$FSUJýFE
*For Diagram see technical section page 19
OCCUPANCY SENSORS
+
WALL SWITCH OCCUPANCY SENSORS
Product Features
t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU
BMNPOEBOECMBDLXJUINBUDIJOH
wall switch cover plate
t$PMPSNBUDIJOHNVMUJTFHNFOUFE
lens
t4FMFDUBCMFBVUPPOBOENBOVBM
on modes
t7BD)[JOQVU
t¡ýFMEPGWJFX
tTRGUNBKPSNPUJPOBOE
TRGUNJOPS
motion coverage area
t-JHIUMFWFMTFOTPS
t8BMLUISPVHINPEF
t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ
and sensitivity
t3FE-&%NPUJPOJOEJDBUPS
t'PSVTFXJUIFMFDUSPOJDBOE
magnetic ballasts
t/POFVUSBMDPOOFDUJPONJOJNVN
 MPBEPSQPXFSQBDLSFRVJSFE
t6-BOED6--JTUFEGPS6OJUFE
 4UBUFTBOE$BOBEB
t5FTUNPEFTFDPOEUJNFEFMBZ
t'JWFZFBSXBSSBOUZ
%VBM$JSDVJU8BMM4XJUDI0DDVQBODZ4FOTPSTJOEFQFOEFOUMZDPOUSPMUXPMJHIUJOHDJSDVJUTXJUI
CJMFWFMTXJUDIJOHUPSFEVDFMJHIUJOHCZXIJDINBZCFSFRVJSFECZFOFSHZDPEFT5IF
dual circuit wall switch occupancy sensor employs passive infrared (PIR) technology and a
EFHSFFTFHNFOUFEMFOTUPBDIJFWFNJOPSNPUJPODPWFSBHFVQUPTRVBSFGFFU
TRNFUFSTUPSFMJBCMZDPOUSPMMJHIUJOHJOPGýDFTDPOGFSFODFSPPNTBOEFNQMPZFFCSFBL
rooms.
Adaptive Technology: New patent pending technology employs advanced algorithms to
achieve convenient energy savings and reduced lamp and ballast maintenance.
Lamp Saver Mode:8IFOUIFMBNQTBWFSGFBUVSFJTFOBCMFEUIFTFOTPSBVUPNBUJDBMMZ
BMUFSOBUFTXIJDIDJSDVJUSFTQPOETUPNPUJPO5IFSFTVMUJTNPSFQSFEJDUBCMFMBNQMJGFBOE
reduced maintenance.
Walk-Through Mode:5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSF
CSJFþZPDDVQJFEBTBS
FTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOB
shorter time delay.
Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off
BSUJýDJBMMJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQS
FTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPX
the threshold, the sensor will turn on articial lighting in occupied spaces.
5IFTFOTPSFBTJMZSFQMBDFTUXPXBMMTXJUDIFTVTJOHFYJTUJOHXJSJOHXJUIOPXJSJOH
modications required. Optional 2-gang wall switch cover plates available in matching colors.
Commercial Grade Occupancy Sensor
Ultrasonic Dual Circuit Wall Switch
%VBM$JSDVJU8BMM4XJUDI
Occupancy Sensor
8