Product specifications
TECHNICAL SPECIFICATIONS
105
GENERAL
Construction
Back Box
In-Ceiling Aluminum
Pendant Aluminum
Heavy-Duty Aluminum
Stainless Steel 316 stainless steel; gray, polyurethane
powder coated finish
Dome Drive Aluminum, thermo plastic
Lower Dome
In-Ceiling Acrylic
Pendant Acrylic
Heavy-Duty Polycarbonate, 0.09-inch thick
Stainless Steel Acrylic
Light Attenuation
Smoked f/0.5 light loss
Clear Zero light loss
Chrome f/2.0 light loss
Gold f/2.0 light loss
Cable Entry (back box)
In-Ceiling 0.75-inch conduit fitting
Pendant Through 1.5-inch NPT pendant mount
Weight (approximate) Unit Shipping
In-Ceiling 5.2 lb (2.4 kg) 8 lb (3.6 kg)
Environmental In-Ceiling 6.2 lb (2.8 kg) 10 lb (4.5 kg)
Standard Pendant 6.5 lb (3.0 kg) 11 lb (5.0 kg)
Environmental Pendant 7.6 lb (3.5 kg) 12 lb (5.4 kg)
Heavy-Duty In-Ceiling* 7.3 lb (3.3 kg) 12 lb (5.4 kg)
Heavy-Duty Pendant* 9.8 lb (4.5 kg) 16 lb (7.3 kg)
Heavy-Duty Environmental
Pendant* 9.8 lb (4.5 kg) 16 lb (7.3 kg)
Stainless Steel 10.1 lb (4.6 kg) 16 lb (7.3 kg)
Environment
In-Ceiling Indoor
Environmental In-Ceiling Outdoor
Pendant, Standard and
Environmental Indoor/outdoor
Heavy-Duty In-Ceiling Indoor
Heavy-Duty Pendant,
Standard & Environmental Indoor/outdoor
Stainless Steel Indoor/outdoor
Operating Temperature
In-Ceiling 32° to 122°F (0° to 50°C)
Standard Pendant (Assumes no wind chill factor)
Maximum 113°F (45°C) absolute maximum; 95°F (35°C)
sustained maximum
Minimum 25°F (–4°C) sustained minimum
Environmental In-Ceiling
and Environmental Pendant (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum; 122°F (50°C)
sustained maximum
Minimum –60°F (–51°C) absolute minimum; prevents
icing at sustained minimum of –50°F (–45°C);
de-ices 0.1 inch (2.5 mm) within 3 hours after
power-up
Heavy-Duty In-Ceiling 32° to 122°F (0° to 50°C)
Heavy-Duty Pendant 32° to 122°F (0° to 50°C) absolute maximum;
32° to 122°F (0° to 50°C) sustained maximum
Heavy-Duty
Environmental Pendant (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum; 122°F (50°C)
sustained maximum
Minimum –60°F (–51°C) absolute minimum; minimal
icing at sustained minimum of –50°F (–45°C);
prevents icing at sustained minimum of –40°F
(–40°C); de-ices 0.1 inch (2.5 mm) within
3 hours after power-up
Stainless Steel (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum; 122°F (50°C)
sustained maximum
Minimum –60°F (–51°C) absolute minimum; minimal
icing at sustained minimum of –50°F (–45°C);
prevents icing at sustained minimum of –40°F
(–40°C); de-ices 0.1 inch (2.5 mm) within
3 hours after power-up
Effective Projected Area (EPA) 20.5 square inches (without mount) 47 square
inches (with IWM Series mount)
MECHANICAL
(Dome Drive Only)
Pan Movement 360° continuous pan rotation
Vertical Tilt Unobstructed +2° to –92°
Manual Pan/Tilt Speeds
Pan 0.1° to 80°/sec manual operation,
150°/sec Turbo
Tilt 0.1° to 40°/sec manual operation
Preset Speeds
Pan 400°/sec
Tilt 200°/sec
For variable-speed operation, an appropriate
controller is required. (With nonvariable
speed control, Spectra IV IP pan/tilt speed is
20°/sec)
AUDIO
Streaming Bidirectional: full or half duplex
Input/Output Terminal block, analog for microphone and
speaker; 600-ohm differential; 1 Vp-p
maximum signal level
Compression G.711 PCM 8 bit, 8 kHz mono at 64 kbit/s
ELECTRICAL
Ports RJ-45 connector for 100Base-TX
Auto MDI/MDI-X
Autonegotiate/Manual setting
Cabling Type Cat5 or better for 100Base-TX
Input Voltage 18 to 32 VAC; 24 VAC nominal
22 to 27 VDC; 24 VDC nominal
Input Power
24 VAC 23 VA nominal (without heater);
73 VA nominal (with heater)
24 VDC 0.7 A nominal (without heater);
3 A nominal (with heater)
Fuse 1.25 A
Auxiliary Outputs 2
Alarm Inputs 7
CERTIFICATIONS/RATINGS/PATENTS
• CE, Class B
• FCC, Class B
• UL/cUL Listed
• C-Tick
• U.S. Patents 5,931,432; 6,793,415 B2; 6,802,656 B2; 6,821,222 B2;
7,161,615 B2
Meets the following standards:
• NEMA Type 4X, IP66 when installed properly (BB4N-F-E, BB4N-PB,
BB4N-PG, BB4N-PG-E, BB4NHD-PG, BB4NHD-PG-E, and BB4N-PSG-E)
• NEMA Type 1, IP40 (BB4N-F and BB4NHD-F)
*Add 2 lb (0.90 kg) to the total weight if the system includes a lower dome cage.
Apac Specbook.book Page 105 Tuesday, November 16, 2010 10:10 AM