Product specifications

304
Pelco by Schneider Electric
3500 Pelco Way, Clovis, California 93612-5699 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com
TECHNICAL SPECIFICATIONS
MODEL
EDI5000-AD2088 Interface that allows serial data communication
between an American Dynamics matrix system
and the Endura video and recording system;
security personnel can use the AD2088 keyboard
to view and control cameras attached to, and
recorded onto, an Endura system through the
existing analog matrix.
GENERAL
Construction Sheet metal
Finish Gray metallic with black end caps, black
matte finish
Operating System Linux
®
COM Ports 2, RS-232
Other Connectors Reserved for future use
LED Indicators Power, COM Port Status,
Network Link/Speed, Network Activity
Reset Button Recessed button with 2 options: reboot and
reset factory default settings
Dimensions 8.21" D x 1.08" W x 6.56" H
(20.85 x 2.74 x 16.66 cm)
Mounting
Desktop Rubber feet (factory-installed)
Wall or Rack Optional mounting accessories required
Unit Weight 2.2 lb (1.0 kg)
Shipping Weight 6.0 lb (2.7 kg)
POWER
Power Input 12 VDC or 24 VAC
Power Consumption 6 W, 0.50 A, 20 BTU/H
Power Connectors
4-pin For RK5200PS-5U or NET5301PS
4-pin to 2-pin adapter For user-supplied power supply
ENVIRONMENTAL
Operating Temperature Range 32° to 122°F (0° to 50°C)
Storage Temperature Range –40° to 149°F (–40° to 65°C)
Operating Humidity 20% to 80%, noncondensing
COMPATIBLE PRODUCTS
Endura System Components The EDI5000 is compatible with Endura
version 1.03 or later components (NVR5100
and SM5000). Endura decoders must be
version 1.04.0032 or later.
POWER SUPPLIES AND ACCESSORIES
RK5200PS-5U Rack mount with power supply (12 units)
NET5301PS Power supply for one data interface (4-pin
connector)
TF2000 Power supply for one data interface (4-pin to
2-pin adapter)
MCS Series Multiple unit power supply, indoor
WM5200-4U Wall mount without power supply (1 unit)
WM5200-4UEXP Wall mount expansion (1 unit)
CERTIFICATIONS
CE, Class B
FCC, Class B
UL/cUL Listed
C-Tick
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred
to in this publication are trademarks of Pelco, Inc. or its affiliates. All other
product names and services are the property of their respective companies.
Product specifications and availability are subject to change without notice.
©Copyright 2010, Pelco, Inc. All rights reserved.
ENDURA
NETWORK
ENDURA WORKSTATION
ENCODER
ENCODER
ENCODER
EDI5000
MATRIX
MATRIX KEYBOARD
MATRIX MONITOR
CAMERA 1
CAMERA 2
CAMERA
CAMERA
CAMERA
NETWORK
SERIAL DATA
LEGEND
VIDEO
DECODER
SAMPLE EDI5000 SYSTEM USING ENDURA FOR EXPANSION
IMPORTANT NOTE: PLEASE READ.
The network implementations in this document are shown as general representations only and are not intended to show detailed network
topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated.
Please contact your local Pelco Representative to discuss your specific requirements.
Apac Specbook.book Page 304 Tuesday, November 16, 2010 10:10 AM