TAC Vista Product Catalog Issue: January 2007
Table of Contents About TAC. ................................................................................................................................................................ 1 System Overview.................................................................................................................................................... 5 Software.................................................................................................................................................
Hardware.................................................................................................................................................................. 25 Ethernet Devices Introduction................................................................................................................................................... 26 TAC Xenta 511/511-B...................................................................................................................................
Network Infrastructure Products Introduction................................................................................................................................................... 70 TAC Xenta 901 Serial LonTalk® Adapter......................................................................................................... 71 TAC Xenta 911..............................................................................................................................................
iv
About TAC Open Systems for Building IT®
Global Leader in Building IT TAC is a leading provider of building automation solutions based on Open Integrated Systems for Building IT. TAC’s mission is to provide added value through building environment services for indoor climate, security and use of energy, delivered with advanced technology to end users and property owners throughout the world.
Support and Energy Optimization We are committed to supporting our customers’ facilities and to ensuring optimum energy performance throughout the entire life-cycle of their buildings.
System Overview Providing Solutions Enabled by Open Systems for Building IT®
VISTA SYSTEM ARCHITECTURE All TAC® products incorporate the TP/FT-10 Free Topology Transceiver TAC VistaTM Workstation TAC Vista Server TAC Vista Webstation Web Client Optional local client Full I/NET or TAC XentaTM 527 Web client Ethernet TCP/IP TAC XentaTM 511 TAC Xenta 527 LonWorks® TP/FT-10 LonWorks® TP/FT-10 Motion Detector Router I/NETTM Network TAC Xenta 104 TAC Xenta 302 and Operator Panel CHW Valve TAC Vista interoperable open systems create seamless integration To satisfy the acceleratin
You will always know what is happening within your control system Alarms and historical logs provide system monitoring that is both reliable and flexible. TAC Vista operators can respond to critical alarms in seconds. The receipt of an alarm can even automatically display a specific system page, giving the operator quick, graphical access to the situation. TAC Vista TAC Vista is the software solution that efficiently controls, checks and analyzes the daily operation and economical running of a building.
TAC MentaTM TAC Menta is the programming software tool for the TAC XentaTM controllers. You will save time and improve operational reliability with this engineering tool for HVAC applications. TAC Menta: • Provides many pre-programmed function blocks and basic application elements • Monitors offline simulations and online testing with an integrated trend log TAC Xenta All TAC Xenta controllers provide open, future-proof system architecture.
Software
TAC Vista 5 Vista 5 Packages The TAC Vista software suite is delivered in the following software installation packages: • TAC Vista Standalone • TAC Vista Standard • TAC Vista Manager • TAC Vista Professional • TAC Vista Enterprise Please refer to the table below for the package contents. Software Part. No.
TAC Vista 5 TAC Vista 5 Server The TAC Vista 5 Server communicates with TAC Xenta controllers or with any LonWorks® product using SNVTs (Standard Network Variable Types). Connection for remote monitoring and/or remote control of TAC systems is by a PC LonTalk® adapter or a dedicated/dial-up line. Geographically remote systems can be connected via a modem. Automatic bi-directional dial-up (Auto Dial) is used for requests, changing values and for transferring alarms.
TAC Vista 5 TAC Vista 5 Workstation Basic software module with color graphics, alarm handling, authority/security, scheduling, trend logging and data backup functionality.
TAC Vista 5 TAC Vista 5 Report Generator Software module that independently generates clear and informative reports and overviews, such as alarm and maintenance reports, status reports, trend logging reports as well as special user-defined reports, diagrams and overviews.
TAC Vista 5 TAC Vista 5 Graphics Editor OGC A high performance stand-alone software module for creating and editing dynamic system images. A broad range of drawing tools, symbols and functions allows customized and efficient color graphic creation. • Extensive standard symbol library • Symbol editor Description • Run time simulation 0-008-8221-0 New License 0-008-8321-0 Upgrade 0-008-8421-0 1 Year Maintenance Agreement • Unrestricted tool positioning • Multiple graphics • Import of .bmp .gif .jpg .
TAC Vista 5 TAC Vista 5 Database Generator Software module for the efficient processing of project specific system data.
TAC Vista 5 TAC Vista OPC Server A software module for open access, via an OPC standard interface, to the TAC Vista 5 server. Provides LonWorks® network object data (nodes, network variables) as OPC objects in a continuously updated database and carries out all the packaging, converting and updating required for these objects.
TAC Vista 5 TAC Vista 5 OPC Tool Software module for the integration of OPC servers into the TAC Vista 5 database (clients). It is easy to operate and based on the Microsoft Windows standard. This minimizes the work required to configure the OPC client in the TAC Vista 5 server database. Structures and objects are imported into this from external OPC servers.
TAC Vista 5 TAC Vista ScreenMate (Virtual Room Unit) Room control via the Intranet on a PC workstation.
TAC Vista FM Vista FM Executive Vista FM TAC Vista FM is a suite of software solutions, built around an integrated database, that gives you a window into the cost and performance of your buildings. It collects and reports – in clear, readable presentations and charts – the information needed to manage operational, system and technical data throughout the building lifecycle.
Engineering Tools Vista FM (continued) new license 0-008-8080-0 0-008-8081-0 0-008-8082-0 0-008-8083-0 0-008-8084-0 0-008-8085-0 0-008-8086-0 0-008-8087-0 0-008-8088-0 0-008-8089-0 0-008-8100-0 0-008-8101-0 0-008-8102-0 0-008-8103-0 0-008-8104-0 0-008-8105-0 0-008-8106-0 0-008-8107-0 0-008-8108-0 MAINTENANCE AGREEMENT TAC Vista FM Base TAC Vista FM Maintenance TAC Vista FM HelpDesk TAC Vista FM Document TAC Vista FM Calculation TAC Vista FM Energy TAC Vista FM LTP TAC Vista FM Contract TAC Vista FM Signat
Engineering Tools TAC ZBuilder TAC ZBuilder is an easy to use and a cognitive tool to configure TAC Xenta 121 zone controllers. It is Windows® based and is fully integrated with TAC Vista and LonMaker® for Windows®. It can also be used as a stand alone tool. Full integration with TAC Vista makes ZBuilder easy to learn and increases the engineering and installation efficiency.
TAC Vista 5 TAC XBuilder TAC XBuilder is the programming tool for TAC Xenta 511, (version 2.0 and later). XBuilder addresses the programming task from the end user point of view, instead of from the device point of view. XBuilder is a project oriented tool, which means all data in an application will be stored in a project container. The user interface is intuitive and customizable with four main windows.
TAC Vista 5 LonMaker Network Management Tool ® High performance network management tool for creating, installing and maintaining multi-vendor, open and interoperable LonWorks® networks. The LonMaker® Management Tool is based on Echelon’s LNS® network operating system, and combines high performance client-server architecture with the user-friendly Microsoft® Visio® user interface.
24 24
Hardware 25
TAC Xenta Ethernet Devices The convergence of Internet and LonWorks® technology creates new opportunities in building automation, and TAC is in the forefront of this development with the concept of Open Systems for Building IT. TAC provides a number of Ethernet devices to let you save a large portion of the infrastructure cost for systems installation by sharing already installed network cables. The table below provides an overview of the Xenta range of Ethernet devices and their functionality.
Ethernet Devices TAC Xenta 511/511-B Web Server ® The TAC Xenta 511 is a web-based presentation system for LonWorks® and Modbus networks. Using a standard web browser, the operator can easily view and control the devices in the LonWorks® network via the Internet or a local intranet. One TAC Xenta 511 can present a small to medium LonWorks® network or be one of several local presentation devices in a larger network.
Ethernet Devices TAC Xenta 527 The TAC Xenta 527 is a comprehensive presentation system, which enables secure web access to both TAC I/NET Seven and TAC VistaTM networks simultaneously. It provides you with the freedom to monitor your system from any location with Internet access. With automatic network discovery of TAC I/NET systems, the only configuration needed is to point the Xenta 527 to TAC I/NET’s NetPlusTM Routers or TAC I/NET Hosts.
TAC Xenta 913 LonWorks® Gateway functional features The TAC Xenta 913 is a cost-effective way to integrate a large variety of products into a TAC network. The TAC Xenta 913 supports the most commonly used open protocols, such as Modbus, BACnet and LonWorks®. It also supports some manufacturer-specific protocols, e.g. I/NET and Clipsal C-bus. The TAC Xenta 913 acts as a gateway, and transfers data point values from one network to another.
Ethernet Devices TAC Xenta 913 LonWorks® Gateway (continued) Specifications Operating voltage . . . . . . . . . . . 24 V AC ±20%, 50/60 Hz or 19–40 V DC Power consumption. . . . . . . . . . max 5 W Transformer sizing . . . . . . . . . . . 5 VA Dimensions. . . . . . . . . . . . . . . . .90 x 110 x 77mm (3.5” x 4.3” x 3”) Enclosure rating. . . . . . . . . . . . . IP 20 Real Time Clock Accuracy at +25°C (77º F). . . . . ±12 minutes per year Power failure protection. . . . . . .
Ethernet Devices TAC Xenta 911 The TAC Xenta 911 communication device can be configured in three different ways: • As a LonTalk® adapter between TAC Vista and a LonWorks® network • As an IP modem, working as a direct replacement for a telephone modem, with dial-up functionality over the computer network • As a remote serial port, meaning the serial port of Xenta 911 can be used as if it was a serial port on the PC. To be used for the serial protocols of Vista.
32
Programmable Controllers 33
TAC Xenta Programmable Controllers TAC Xenta is a range of LonMark®-certified programmable controllers intended for control of small, medium and large heating, ventilation and air-conditioning systems. TAC Xenta series controllers are designed for use in open systems and for integration via LonWorks® – an industrial standard for network communications which enables a range of different systems within a property, such as HVAC, lighting and access control, to be integrated on the same network.
TAC Xenta Programmable Controllers Overview Controllers Device Xenta 281 Usage Xenta 282 Xenta 283 Small installations Xenta 301 I/O modules Xenta 302 Medium size installations Xenta 401 Xenta 411/412 Xenta 421A/422A Large installations 12 16 12 20 20 10 9 Digital Inputs, DI 2 2 2 4 4 10 4 2 4 4 4 4 4 Universal Inputs, UI 4 4 10 8 8 8 3 4 Digital Outputs Triac, DO Analog Outputs, AO Xenta 491/492 8 Analog Inputs, AI Digital Outputs Relay, DO Xenta 471 I/O exten
Programmable Controllers TAC Xenta 280 A compact, freely programmable controller which is LonMark® certified and has fixed inputs and outputs.
Programmable Controllers TAC Xenta 300 Stand Alone A compact, freely programmable controller which is LonMark® certified and has 20 fixed inputs and outputs. The controller can be expanded to up to 40 inputs/outputs using two expansion modules. It does not include peer-topeer or BMS communication. The controller can be upgraded at any time to a networkable version without changing the hardware. The TAC Xenta OP Operator Panel and a compatible terminal block are included in the standalone package.
Programmable Controllers TAC Xenta 300 Base Unit A compact, networkable, freely programmable controller which is LonMark® certified and has 20 fixed inputs and outputs. It can be expanded for up to 40 inputs/outputs using 2 expansion modules. Data can be directly accessed on site using a TAC Xenta OP Operator Panel. Specifications Operating voltage . . . . . . . . . . . . . . . . . . 24 V AC/DC ±20%, 50/60 Hz Power consumption. . . . . . . . . . . . . . . . . max.
Programmable Controllers TAC Xenta 401 and 401:B Base Unit High performance, freely programmable, high end controller without its own physical inputs and outputs. LonMark® certified. It can be expanded for up to 100 inputs/outputs with 10 expansion modules. It has a large memory so that the controller can be easily used for higher level functions (e.g. centralized schedule management). Specifications Operating voltage . . . . . . . . . . . . . . . . . . .
Programmable Controllers TAC Xenta 411/412 Digital Input Module For monitoring and counting digital, dry contact signals. The digital input module is only to be used in combination with the TAC Xenta 300/401 basic controllers. The module is available either with or without status LEDs. The terminal block is not part of the electronic unit and must be ordered separately. Specifications functional features Operating voltage . . . . . . . . . . . . .
Programmable Controllers TAC Xenta 421A and 422A Universal Input and Digital Output Module functional features • Universal inputs provide installation flexibility • Designed for TAC Vista and open standard LonWorks systems • Perfect for distributed installations • Manual override switches provide local bypass operation • Cost-effective installation and maintenance using separate terminal base and plug-in electronic units • Individually configurable using the TAC Menta programming tool TAC Xen
Programmable Controllers TAC Xenta 451A and 452A Universal Input and Analog Output Module TAC Xenta 451A and 452A are Universal Input/Analog Output modules in the TAC Xenta family. They can be used as normal Xenta I/O modules or as certified LonMark® devices.
Programmable Controllers TAC Xenta 471 Analog Input Module For connecting analog, active, current and voltage signals. The analog input module is only to be used in combination with the TAC Xenta 300/401 basic controllers. Specifications Operating voltage . . . . . . . . . . . . . 24 V AC ±20%, 50/60 Hz, 19 - 40V DC functional features • Universal inputs provide installation flexibility • Designed for TAC Vista and open standard LonWorks systems Power consumption . . . . . . . . . . . . max.
Programmable Controllers TAC Xenta 491/492 Analog Output Module For issuing analog actuating signals. The analog output module is only to be used in combination with the TAC Xenta 300/401 basic controllers. The TAC Xenta 492 is equipped with manual override switches for the analog outputs. Specifications Operating voltage. . . . . . . . . . . . 24 V AC/ ±20%, 50/60 Hz, 19 - 40V DC functional features Power consumption. . . . . . . . . . . max.
Programmable Controllers TAC Xenta Operator Panel For convenient local operation of TAC Xenta controllers. Input is via 6 control keys and information is displayed in the clear LCD display. The LCD display’s background lighting can be switched off, if not required, by changing the relevant parameter. The operator panel is connected to the controller with a plug-and-socket connection and supplied with power through the cable connector. It can also be directly connected to the LonWorks network.
46
Zone Controllers 47
TAC Xenta Zone Controllers functional features • Air-quality control with CO2 measurement • PI control with P-band and I-time setting • Seven different types of operation • Neutral zone between heating and cooling • On demand override of the wall module by the occupancy sensor, window contact or bypass control switch • Individual setpoint adjustment • Zone sensors with the ability to connect to a TAC Xenta LonWorks Operator Panel • LonMark® certified 48 TAC Xenta zone controllers are indiv
TAC Xenta Zone Controllers Overview Controllers Xenta Xenta 101-VF 121- FC Applications Fan Coil Fan Coil Heating & air conditoning t t 3 speed fan t t t t t On/ off fan Xenta 102-B Xenta 102-EF Xenta 102-VF Xenta Xenta 102-ES 102-AX Variable air volume (VAV) Xenta 103-A Xenta 104-A Xenta 110-D Xenta 121-HP Chilled Ceiling Roof Top Dual Zone Heat Pump t VAV t VAV with electric heater t t t t t VAV with hot water battery 0-10 V control t 3 point control t VAV with on-
TAC Xenta 101-VF Fan Coil Unit Controller LonMark® certified individual room controllers for fan coil systems with heating and/or cooling. The heating/cooling switch can be centrally controlled, or controlled via the average temperature. Incoming air and room temperature can be controlled in sequence. Fans are controlled continuously, 3-speed or on-off depending on the fan coil controller type. The controller can be operated in a stand-alone system or within a LonWorks® network.
Zone Controllers TAC Xenta 102-B, 102-EF, 102-VF VAV Controllers functional features • Various applications: Single-step control with setpoint calculation of an external air flow controller. Two-step setting with cooling and heating in sequence. Heating operation via an electric reheater or hot water. • Slave function mode of operation and setpoint for several slave controllers are controlled by one master. • Setpoint adjustment via a wall module with setpoint adjuster or via a LonWorks® network variable.
Zone Controllers TAC Xenta 102-ES VAV Controller functional features • Various applications: Single-step control via external air flow sensor and heating in sequence. Heating operation by modulating hot water radiator valve. • Slave function mode of operation and setpoint for several slave controllers are controlled by one master. • Setpoint adjustment via a wall module with setpoint adjuster or via a LonWorks® network variable.
Zone Controllers TAC Xenta 102-AX VAV Controller with Onboard Actuator and Air Flow Transducer functional features • Various applications: Single-step VAV controller via internal air flow sensor and heating in sequence up to 3 stages. • Setpoint adjustment via STR 200, 202 or 250 wall modules or via a LonWorks® network variable. • Seven modes of operation: occupied, standby, bypass, unoccupied, morning warm up, purge mode and emergency pressurization/ depressurization.
Zone Controllers TAC Xenta 103-A Chilled Ceiling Controller functional features • Various applications: Room temperature control via chilled ceiling, in sequence with damper and radiator valve modulating the hot water. Choice of heating/cooling, only heating or only cooling (water and/or air). • Slave function mode of operation and setpoint for several slave controllers are controlled by one master controller.
Zone Controllers TAC Xenta 104-A Roof Top Unit Controller functional features • Various applications: Single-step control with cooling, heating or changeover operation for cooling/heating. Two-step control with sequential cooling and heating. LonMark® certified controller for small air handling systems and roof top units for heating, cooling and heat recovery. The room temperature is held at a constant temperature with sequential control of the heating, cooling and heat recovery functions.
Zone Controllers TAC Xenta 110-D Dual Zone Controller functional features • Various applications: Single-step control with cooling or heating. LonMark® certified individual room controllers for cost-effective individual room solutions of climate control, lighting control, dimming and window control. Seven LonMark® profiles are available for various applications.
Zone Controllers TAC Xenta 121-FC Programmable Fan Coil Controller TAC Xenta 121-FC is an easily programmable controller intended for both 2-pipe and 4-pipe applications, with or without re-heat. It can be configured for use with a multitude of valve actuator types, such as on/off, multistage, increase/decrease, PWM, etc. The controller has different types of fan control and advanced fan control functions, including on/off delays, boosting and conditioning.
Zone Controllers TAC Xenta 121- HP Programmable Heat Pump Application functional features • The controller is designed for both water-sourced and airsourced heat pump installations • Multi-functional Heating and Cooling: the controller handles heating, cooling and secondary heating • Multi-stage Fan Control: The Xenta 121 controller handles up to three stages or analog speed control • Indoor Air Quality Control functions: Full support for CO2 and RH (Relative Humidity) functions • Exception modes take car
Zone Controllers TAC Xenta OP LonWorks® Operator Panel functional features • Accesses the TAC Xenta network for values, parameters, alarms and time schedules • Supports local characters • Access Xenta 100/120 via STR module • Any LonWorks device can be connected • Silicone buttons For convenient local operation of TAC Xenta controllers and individual room controllers. Input is via 6 control keys. Information is shown on a clear LCD display.
60
Security 61
TAC Vista Security Controllers TAC Vista Security provides a complete security solution that is fully integrated with Vista, using your building’s administrative TCP/IP network. Security devices and building control devices can share information, connected through a common architecture and network. Simple to install TAC Vista Security is designed to be easy to install.
Security TAC Xenta 527 The TAC Xenta 527 is a comprehensive presentation system, which enables secure web access to both TAC I/NET Seven and TAC VistaTM networks simultaneously. It provides you with the freedom to monitor your system from any location with Internet access. With automatic network discovery of TAC I/NET systems, the only configuration needed is to point the Xenta 527 to TAC I/NET’s NetPlusTM Routers or TAC I/NET Hosts.
Security 7790A MCI MicroController Interface functional features • Integration – Environmental – Access Control – General Purpose • MicroControl units supported – 123 Series MicroRegulatorsTM – SCU1284 Security Control Unit – SCU1280 Security Control Unit – SCU1200 Security Control Unit • Peer-to-Peer, Token Passing LAN standard • Dual MicroController Sub-LANs – 16 SCUs per MCI – 64 MRs per MCI – 64 MicroControl Units per MCI (SCU and MR combined) – Mix and Match Controllers on the Sub-LANs The TAC I/NET
Security 7798 I/SITE™ LAN Integrated Site Controller functional features • ViewCon™ keypad display – Built-in operator interface – Custom pages & standard summaries – Password protected • Sub-LAN port for connection of up to 32 MicroRegulatorsTM and/or Door Processor controllers in any combination – Open or closed loop sub-LAN – Communications through both primary and alternate paths • Local Port for PC or Printer • Local Port for Auto Dial/Auto Answer modem • Attractive plastic enclosure suitable for wal
Security TAC I/NET Security Control Unit Models 1284, 1280, 1200 • Robust, stand-alone four-door access controller The SCU (Security Control Unit) family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring features. Three versions of the SCU are available. The SCU1284 is a door controller for up to 4 doors, with 12 supervised inputs and 8 Form C relay outputs.
Security 7798C (SLI) Sub-LAN Interface The 7798C sub-LAN interface (SLI) functions as an intelligent hub managing a network of MicroControllers and other controllers in a larger TAC I/NETTM distributed control system.
68
Network Infrastructure Products 69
TAC Xenta Network Infrastructure TAC Network infrastructure product line enables seamless integration between IP network, field buses and telephone lines. It gives a variety of methods to connect a PC to the network. It includes a gateway for I/Net to be integrated into TAC Vista. It allows for optimized LonWorks® network design and structure also using different types of routers, both for Lon to Lon and IP to Lon connections.
Network Infrastructure TAC Xenta 901 Serial LonTalk® Adapter functional features • Works as a dial-up LonTalk® adapter The TAC Xenta 901 is a serial LonTalk® adapter, designed to let TAC Vista reach a LonWorks® network via a dial-up line. When the modem line between TAC Xenta 901 and TAC Vista has been established, communication proceeds as if TAC Vista had been connected directly to the LonWorks® network. The dial-up can either be initiated by TAC Vista, or by the TAC Xenta 901 unit.
Network Infrastructure TAC Xenta 911 The TAC Xenta 911 Communication device can be configured in one of two ways: • as a LonTalk® adapter between TAC Vista and a LonWorks® network • as an IP modem, working as a direct replacement for a telephone modem, with dial-up functionality over the computer network In the first case, TAC Xenta 911 is either always connected to TAC Vista, or can use the “low bandwidth” configuration to allow many more networks connected to TAC VIsta.
Network Infrastructure PC LonWorks® Adapter PC interface card for connecting the LonWorks® network to a TAC Vista central system or to a network management tool.
Network Infrastructure Serial LonWorks® Adapter External LonWorks® interface for serial connection between equipment such as PCs and modems and the LonWorks® network. Can be wall mounted. • Interface between LonWorks® and RS-232 interface • External device, no plug-in slot in PC necessary Specifications Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 30 V AC/DC functional features Power consumption . . . . . . . . . . . . . . . . . . . . . . . . .
Network Infrastructure Termination Terminating resistor for FTT-10 and TP/XF-1250 network segments. Description 0-073-0905-1 Termination FTT-10 9-073-0020-0 Termination TP/XF-1250 TAC Xenta 913 LonWorks®/INET Gateway functional features The TAC Xenta 913 is a cost-effective way to integrate a large variety of products into a TAC network. The TAC Xenta 913 supports the most commonly used open protocols, such as MODBUS, BACnet and LonWorks®.
Network Infrastructure TAC Xenta 913 LonWorks®/INET Gateway (continued) Specifications Operating voltage . . . . . . . . . . . 24 V AC ±20%, 50/60 Hz or 19–40 V DC Power consumption. . . . . . . . . . max. 5 W Transformer sizing . . . . . . . . . . . 5 VA Dimensions. . . . . . . . . . . . . . . . .90 x 110 x 77mm (3.5” x 4.3” x 3”) Enclosure rating. . . . . . . . . . . . . IP 20 Real Time Clock Accuracy at +25°C (77º F). . . . . ±12 minutes per year Power failure protection. . . . . . .
Network Infrastructure LonWorks® Terminal Units TP/FT-10,TP/LPT-10, and TP/XF-1250 networks need to be terminated using a defined network terminator. L-Term offers two standard network terminators in one slim housing, which makes them a perfect solution to be used with the active network infrastructure products (e.g. L-IP, L-Switch, etc.). The LT-33 network terminator can be used to terminate two TP/FT-10 and TP/LPT-10 channels in bus or in free topology.
Network Infrastructure LonWorks® LCD Display L-VIS impresses by its timeless design, harmonic integration into modern and historical architecture as well as its extremely user friendly concept.
Network Infrastructure LonWorks® Routers The L-Switch Router is the solution to interconnect multiple LonWorks® (EIA709) channels. It provides up to five ports and routes packets between these ports. In spite of its small size the L-Switch router provides best class performance and flexibility in use. In order to provide the optimal router configuration the L-Switch supports 2 to 5 ports as well as the 2 operating modes “Smart Switch Mode” and “Configured Router Mode”.
Network Infrastructure LPA Protocol Analyzer LPA-SET-IP functional features • Runs on Windows 2000/XP® • Supports the LOYTEC Multiplexed Network Interface Technology (MNI) • The LPA software supports both EIA-709 and LonMark® IP-852 on Ethernet • Remote LPA function with LPA-IP and L-IP • Online packet monitoring • High resolution packet timestamping • Comprehensive packet filter functions on each layer of the network protocol The family of LPA Protocol Analyzers listens on LonWorks® (EIA-709) or LonWork
Network Infrastructure LonWorks® Network Interfaces, NIC The NIC’s are the world’s fastest and most universal network interfaces for LonWorks® (EIA-709) and Ethernet (EIA-852) channels. Based on the revolutionary ORION and L-Chip technology, they offer the highest packet update rates and lowest response times on the market. functional features • Network Interface for EIA-709 and EIA-852 (IP-852) network channels. • Best performance, highest packet throughput.
Network Infrastructure LonWorks® (EIA-709) – IP Routers Gateway The L-IP fills the gap between LonWorks® (EIA-709) installations and IP networks. It can tunnel LonWorks® packets back and forth through an arbitrary IP-based network, such as a LAN, an Intranet, or even the Internet. The L-IP connects to the IP network via an Ethernet channel. Available LonWorks® transceivers include FT-10 and TP-1250.
Operator Panels 83
Xenta Operator Panels • Presents variables and parameters on the network • No configuration required • Enables access to the entire network via a local connection • Provides the possibility of publicly displaying data of common interest, such as the outdoor temperature 84 The TAC Xenta Operator Panel is a compact, and versatile display unit, which can be mounted in a cabinet or used hand-held.
Operator Panels TAC Xenta Operator Panel For convenient local operation of TAC Xenta controllers. Input is via 6 control keys and information is displayed in the clear LCD display. The LCD display’s background lighting can be switched off if required by changing the relevant parameter. The operator panel is connected to the controller with a plugand-socket connection and supplied with power through the cable connector. It can also be directly connected to the LonWorks® network.
Operator Panels TAC Xenta OP 1500 The TAC OP 1500 is a rugged PC designed for industrial applications. It is built around an IP65 front panel with a 15” color TFT LCD screen and a high-definition analog touch panel. The TAC OP 1500 is used as a web client for TAC Vista Webstation, TAC Xenta 511, or other information systems. It is compact and easy to install and setup. No software installation is required. Once connected it is ready to run.
Air Handling Controllers 87
TAC Air Handling Controllers The TAC 2000 ventilation controller family provides a series of advanced system solutions for control, monitoring and supervision of air handling units in buildings. The software package In TAC 2000 Viewer is used to monitor and supervise the controller.
Air Handling Controllers TAC 2411, 2412 and 2413 The TAC 2000 family now includes a series of advanced system solutions for air handling. They are complete solutions for complete control, monitoring and supervision of air handling units in buildings. The following controllers are available: • TAC 2411 offers a rational and efficient solution to air handling where the heating coil controls the room or supply air temperature.
Air Handling Controllers TAC 2000 Viewer functional features • Dynamic Colorgraphic TAC 2000 Viewer is a PC-based presentation system for all controllers in the TAC 2000 Ventilation Family (TAC 2411, TAC 2412 and TAC 2413). It is an effective tool for commissioning, operation, and fault finding in air handling systems. By connecting the TAC 2000 Viewer to the controller, you can easily and quickly access all important information in the air handling system.
Heating Controllers 91
TAC Heating Controllers TAC offers a series of heating controllers with and without communication possibilities. All control the radiator system according to an outdoor temperature-compensated reset curve and a reference sensor. The controllers also control the domestic hot water.
Heating Controllers TAC 2112 The TAC 2112 offers control of hot water heating systems. The radiator circuit is controlled according to an outdoor temperature-compensated reset curve and reference sensor. Simple symbols, a clear LCD display and a minimum number of buttons make it easy to read and change the values. There are three adjustable curve points where you can adjust the reset curve exactly to suit different heating systems.
Heating Controllers TAC 2222 The TAC 2222 offers combined heating and domestic hot water control for hot water heating systems. The radiator circuit is controlled according to an outdoor temperature compensated reset curve and reference sensor. The domestic hot water is controlled by using a separate constant temperature controller.
Heating Controllers TAC 2232 District Heating Compensator/ Optimizer functional features • Automatic adjustment of the reset curve The TAC 2232 offers combined heating and domestic hot water control for hot water heating systems. The controller is intended for three stage district heating. The radiator circuit is controlled according to an outdoor temperature-compensated reset curve and reference sensor. The domestic hot water is controlled by using a separate constant temperature controller.
Heating Controllers TAC 2242 Heating Compensator/ Optimizer The TAC 2242 offers combined heating and domestic hot water control for hot water heating systems. The radiator circuit is controlled according to an outdoor temperature compensated reset curve and reference sensor. The domestic hot water is controlled by using a separate constant temperature controller.
Heating Controllers TAC 2321 District Heating Compensator The TAC 2321 offers combined heating and domestic hot water control for district heating systems. The radiator circuit is controlled according to an outdoor temperature compensated reset curve and reference sensor. The domestic hot water is controlled by using a separate loading controller.
Heating Controllers TAC 2000 Viewer for TAC 2000 Heating Controllers functional features • Dynamic Colorgraphic • Trend log viewer • List of all parameters in the controller • Status of In- and outputs • Direct connection or dialed up via modem TAC 2000 is a PC-based information tool intended for commissioning, operation and troubleshooting in heating systems with controllers belonging to the TAC 2000 family.
Heating Controllers TA 200 Reset Controller TA 200 is an Outdoor Reset Controller for outdoor reset control of heating systems. It can be used for conventional supply temperature control of mixing valve systems for radiator or floor heating. It can also be used for two or three stage on/off control of gas boilers. With a room sensor, automatic reset of the supply temperature from the room temperature can be obtained.
Heating Controllers TA 200 OPT Heating Compensator and Optimizer TAC 200 OTP is a heating compensator complete with optimizer control of the boiler. It can be used for conventional supply temperature control of mixing valve systems for radiator or floor heating. It can also be used for two stage on/off control of gas boilers.
Heating Controllers TA 239W Domestic Hot Water Temperature Controller The TA 239W controller is part of the C80 system and is designed for the control of domestic hot water systems. The output is a 2–10 V or a 0–10 V signal, which can position one or up to 10 actuators of the EM type in parallel. The setpoint can be increased or decreased via the SPC input. functional features For best results, the TA 239W should be used in combination with a fast temperature sensor.
Copyright © 2007, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. All rights reserved. CAT-VISTA-A4 01/07 www.tac.