Datasheet

72 INSTALLATION MATERIAL/THORSMAN/MC1038INT/GB
Grommets, TET (IP 67)
Pull the cable back gently to lock it. The
grommet is ready.
Puncture the diaphragm using the wires from
which the outer sheath has been removed.
Press the grommet into the hole.
Basic Data
Suitable for
Untapped holes of 0.5 to 4-mm
thick material.
Applications
For completely dust and water-
tight cable and pipe inlets, for ex-
ample in cars, aeroplanes, ships,
electrical and hydraulic equipment,
enclosed apparatus and light fit-
tings.
Advantages
Fast installation – seals without
tightening (S 55, IP 67)
Permits vibration in cables and
pipes without detracting from
the seal
The sealing diaphragm is punc-
tured only when the cable is
drawn through – acts as a blind
plug and is ready for installation
Approved for installation in
ships
Each size has a very wide seal-
ing range
Approval
Approved by Lloyds and the Swe-
dish, Norwegian, Danish and Fin-
nish national approval boards for
watertight penetration.
Class of enclosure
IP 67 in accordance with IEC.
Material
Ethylene propylene diene mono-
mer (EPDM) grey. Chloroprene
(CR) black.
m10900
m10890
m10880
Range/Technical Data
1)
Tolerance if material thickness is minimum 2 mm; +1, –0 mm.
Tolerance if material thickness is maximum 2 mm; ±1 mm.
2)
Tolerance ±0.5 mm.
Colours: EPDM, grey and CR, black.
P1052
Type Material Hole
1)
Sealing Measurements, Article No.
mm range mm mounted T-
AB
TET ␣ 3–5 EPDM 12.5
2)
3-5 5 20 3258 206
TET ␣ 5–7 16 5-7 7 21 3265 022
TET ␣ 7–10 19 7-10 8.5 24 3260 007
TET 10–14 23 10-14 10 28 3261 005
TET 14–20 29 14-20 12 35 3262 003
TET 20–26 38 20-26 16 46 3263 027
TET 26–35 48 26-35 20 58 3264 025
TET ␣ 3–5 CR 12.5
2)
3-5 5 20 3258 244
TET ␣ 5–7 16 5-7 7 21 3265 048
TET ␣ 7–10 19 7-10 8.5 24 3260 049
TET 10–14 23 10-14 10 28 3261 047
TET 14–20 29 14-20 12 35 3262 045
TET 20–26 38 20-26 16 46 3263 043
TET 26–35 48 26-35 20 58 3264 041