User Manual

14 of 30
5200WHC2 Wiser Home Controller 2 Installation Instructions
© 2013 Schneider Electric. All Rights Reserved.
C-Bus Network Devices
In order to collect C-Bus network information (for PICED), the Wiser 2 must be connected
to an active C-Bus network. Be sure to use Cat.5e UTP cable that is certified for use on
C-Bus networks; catalogue number 5005C305B (solid), 5005C305BST (stranded).
The Wiser 2 uses a 2-terminal plug for C-Bus. This avoids the possibility of wiring the
C-Bus network to the Ethernet LAN.
C-Bus Toolkit software (installed earlier on the PC) allows you to get the unit addresses
and group addresses that are used by PICED to create a project for device monitoring and
control.
Do not run C-Bus Toolkit software and PICED software at the same time on your PC. Both
applications use the C-Gate program but in slightly different modes of operation.
To use C-Bus Toolkit with the Wiser Home Controller 2, do the following:
1. If Toolkit cannot find an IP address for the Wiser 2, then press the Scan Network button
on the toolbar.
2. Use the tools provided to scan the network, search for networks, or refresh the list of
projects, as needed. Refer to Toolkit’s help files for more information.
3. If you have difficulty accessing the C-Bus network using C Bus Toolkit, check the cable
connection at the rear of the Wiser 2. Look for LED indications of a problem.
4. After you have updated the Tag database using C-Bus Toolkit, save the project and shut
Toolkit down before opening PICED.
C-Bus cable
Use Category 5e Unshielded Twisted Pair (UTP) network cable.