Installing the wire extender kit in a humidity control system
STAT EQUIP
C RCY
CG
W C
RH
C
G
W
DEHUMIDIFIER
RC RH Y W
2
+ -
WISER AIR
20
The wire extender can be used to install dehumidication devices. In order to utilize
this function, set up the wiring as shown below:
Connect the W2 terminal (as required) with the extender kit W terminal.
Remove the jumper wire between the Y and W, and Rc and Rh terminals on the
extender kit.
Use the W and Rh terminals for the dehumidier.
The Wiser Air common wire should be connected to the C terminal on the STAT
side of the extender kit.